{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E09008F7IN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E09008F7IN","canonicalUrl":"https://aoctrl.com/schneider/LC1E09008F7IN","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E09008F7IN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys contactor, LC1E09008F7IN, 4P (2 NO + 2 NC), AC-1 ≤415 V 40 A, 110 V AC coil, DIN-rail mount.","salesMarkdown":"The Schneider Electric LC1E09008F7IN is a 4-pole Easy TeSys contactor with a 110 V AC coil, wired 2 NO + 2 NC. It is rated for 40 A in AC-1 utilisation category at up to 415 V, making it a straight resistive-load switching part — heaters, ovens, incandescent lighting banks, or any load where inrush stays under 1.5× running current. Depth is 80 mm, height 74 mm — no surprises for an existing Easy TeSys cutout. ## What the AC-1 rating means for your BOM line AC-1 is the utilisation category for resistive or slightly inductive loads — the contactor sees near-zero inrush and switches at power factor near unity. The 40 A figure at 415 V is the thermal current (Ith) under those conditions. If your load is a motor (AC-3) or a transformer (AC-6a), this contactor is not the right pick; in those categories the make/break current is far lower. For a resistive bank or a resistance heater string, this is the correct duty class and the rating is honest at 40 A. IP2X finger-safe front. Mounts on DIN rail or plate. The 4-pole layout with 2 NO + 2 NC gives you one normally-open and one normally-closed pair on each side of the contactor — useful for interlocking or status feedback without adding a separate auxiliary block. Permissible ambient during operation is -5 to 55 °C; storage range is -60 to 80 °C. Vibration resistance: 1.5 Gn open, 3 Gn closed across 5–300 Hz. Shock resistance: 7 Gn open, 10 Gn closed for 11 ms.","metaTitle":"Schneider LC1E09008F7IN Easy TeSys Contactor, 40A AC-1, 110V","metaDescription":"Active production LC1E09008F7IN 4P (2NO+2NC) contactor rated 40A at 415V AC-1 for resistive loads. 110VAC coil, DIN-rail mount. EN/IEC 60947 certified.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"80 mm","Range":"Easy TeSys","Width":"45 mm","Height":"74 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"DIN rail Plate","Non-overlap time":"1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"4P","Operating altitude":"3000 m","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068","Utilisation category":"AC-1","Contactor application":"Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)","IP degree of protection":"IP2X conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/LC1E09008F7IN/easy-tesys-contactor-4p2-no-+-2-nc-ac1-415-v-40a-110-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E09008F7IN/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this contactor?","answer":"40 A at 415 V in AC-1 utilisation category (resistive load). 4 poles configured 2 NO + 2 NC. Coil is 110 V AC. Mounts on DIN rail or plate, 45 mm wide."},{"question":"What standards does this contactor comply with?","answer":"EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and the Chinese GB/T 14048 equivalents. Fire resistance to 850 °C per IEC 60695-2-1."},{"question":"Can this contactor switch motor loads?","answer":"No — it is rated only for AC-1 (resistive) duty. For motor starting (AC-3), a different contactor with a higher make/break capacity is required."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E09008F7IN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E09008F7IN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}