{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E09008N7IN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E09008N7IN","canonicalUrl":"https://aoctrl.com/schneider/LC1E09008N7IN","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E09008N7IN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control, LC1E09008N7IN, 4P (2NO+2NC) contactor, AC-1 resistive load, 25 A at ≤415 V, obsolete.","salesMarkdown":"The Schneider Electric LC1E09008N7IN is a 4-pole contactor from the Easy TeSys Control range, configured 2NO+2NC, rated for AC-1 resistive load switching at 25 A up to 415 V. It is designed for resistive load applications — think heater banks or lighting circuits — not motor starting. The AC-1 utilisation category tells you the contacts are rated for the lower inrush of resistive loads, not the high locked-rotor current of a motor. Mounts on DIN rail or a plate — the 45 mm wide footprint fits standard panel cutouts alongside other Easy TeSys components. The contactor includes a guaranteed non-overlap time of 1.5 ms between NC and NO contacts on both energisation and de-energisation, which prevents momentary short-circuits in interlocking circuits. Rated for operation up to 3000 m altitude and -20 to 70 °C ambient at coil voltage, with storage down to -60 °C. The TH protective treatment (pollution degree 3) means it handles the damp, mildly corrosive conditions typical of industrial control panels. We can quote to order against an RFQ from our multi-source network, but expect last-time-buy dynamics on availability. No official successor order code is listed in the lifecycle record. If you need a drop-in replacement, a cross-reference to a current Easy TeSys or TeSys Deca contactor with the same coil voltage and pole configuration will require a parametric check — the 45 mm width and DIN-rail mounting are standard, but verify the control circuit ratings match.","metaTitle":"Schneider LC1E09008N7IN Easy TeSys Contactor, 25A AC-1, 4P","metaDescription":"Obsolete LC1E09008N7IN contactor from Schneider Easy TeSys Control. 25A AC-1 resistive load, 4P (2NO+2NC), 415V. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"80 mm","Range":"Easy TeSys","Width":"45 mm","Height":"74 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"DIN rail Plate","Non-overlap time":"1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"4P","Operating altitude":"3000 m","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068","Utilisation category":"AC-1","Contactor application":"Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)","IP degree of protection":"IP2X conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6b19b5cdde6e156c223dd1ef3182a617.pdf","sourceUrl":"https://www.se.com/sg/en/product/LC1E09008N7IN/contactoreasy-tesys-controllc1e4p2no+2ncac1415v25a415v/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E09008N7IN/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this contactor?","answer":"It is a 4-pole (2NO+2NC) contactor rated 25 A in AC-1 (resistive load) at ≤415 V. The coil voltage is not listed in the available spec data — confirm from the nameplate or original BOM."},{"question":"How do I source this obsolete part?","answer":"Through surplus or independent distributor channels. Submit an RFQ for a quote — availability varies and is not stockable long-term."},{"question":"What standards does this contactor comply with?","answer":"It complies with EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and the Chinese GB/T 14048.1, 14048.4, and 14048.5. Fire resistance is 850 °C per IEC 60695-2-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E09008N7IN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E09008N7IN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}