{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E09008P7IN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E09008P7IN","canonicalUrl":"https://aoctrl.com/schneider/LC1E09008P7IN","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E09008P7IN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control contactor, LC1E09008P7IN, 4P (2NO+2NC), AC-1 ≤415V 25A, 230V coil, DIN rail mount.","salesMarkdown":"The Schneider Electric LC1E09008P7IN is a 4-pole (2NO+2NC) contactor from the Easy TeSys Control range, rated for 25 A in AC-1 utilisation category at ≤415 V with a 230 V coil. The AC-1 25 A rating governs resistive loads — heaters, lighting banks, or any load where inrush is negligible. This is not a motor-contactor rating (AC-3); if your application switches inductive motor loads, this contactor is not the right choice. The 4-pole arrangement with 2 normally-open and 2 normally-closed contacts gives flexibility for interlocking or dual-load switching in a single package. The guaranteed 1.5 ms non-overlap time between NC and NO contacts on both energisation and de-energisation is a safety-relevant spec for applications requiring break-before-make isolation. Depth is 80 mm, height 74 mm — factor that into enclosure layout and gland-plate clearance. IP2X protection means it is finger-safe but not sealed against dust or moisture; keep it inside a panel. The TH protective treatment (pollution degree 3 per IEC 60068) suits it for industrial environments with moderate conductive pollution. Operating altitude is rated to 3000 m without derating. ## Compliance & Environmental Fire resistance is tested to 850 °C per IEC 60695-2-1. Vibration resistance is 1.5 Gn (contacts open) and 3 Gn (contacts closed); shock resistance is 7 Gn open, 10 Gn closed — figures that matter for transport and machine-mounted applications.","metaTitle":"Schneider Electric LC1E09008P7IN Easy TeSys Contactor, 4P, 2","metaDescription":"Schneider Electric LC1E09008P7IN Easy TeSys Control contactor, 4P (2NO+2NC), 25A AC-1 at ≤415V, 230V coil. Obsolete — sourced to order against RFQ. DIN rail mount, EN/IEC 60947 com","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"80 mm","Range":"Easy TeSys","Width":"45 mm","Height":"74 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"Plate DIN rail","Non-overlap time":"1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"4P","Operating altitude":"3000 m","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068","Utilisation category":"AC-1","Contactor application":"Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)","IP degree of protection":"IP2X conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/60d7fcb9a78acb0237154e76c12d6b5c.pdf","sourceUrl":"https://www.se.com/sg/en/product/LC1E09008P7IN/contactoreasy-tesys-controllc1e4p2no+2ncac1415v25a230v/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E09008P7IN/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to LC1E09008P7IN?","answer":"There is no official direct replacement listed by the manufacturer. Any substitute must match the 4P (2NO+2NC) configuration, 25 A AC-1 rating at ≤415 V, and 230 V coil voltage. An RFQ is the best way to identify a suitable cross-reference from current production."},{"question":"What are the key ratings of this contactor?","answer":"It is a 4-pole (2NO+2NC) contactor rated 25 A in AC-1 utilisation category at ≤415 V, with a 230 V coil. It is designed for resistive load switching and mounts on a DIN rail."},{"question":"What compliance standards does this contactor meet?","answer":"It complies with EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and the Chinese GB/T 14048 series. Fire resistance is tested to 850 °C per IEC 60695-2-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E09008P7IN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E09008P7IN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}