{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E0901E7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E0901E7","canonicalUrl":"https://aoctrl.com/schneider/LC1E0901E7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E0901E7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control, LC1E0901E7, 3P(3NO) contactor, AC-3/AC-3e ≤440V 9A, 48V AC coil 50/60Hz, 1NC auxiliary contact.","salesMarkdown":"The LC1E0901E7 is a 3-pole contactor from the Easy TeSys Control range, rated 9 A in AC-3 utilisation category at up to 440 V. That AC-3 rating tells you it's sized for starting and stopping squirrel-cage motors — the 9 A figure governs the motor full-load current it can switch, not the resistive heating current. For resistive loads (AC-1), the same contactor carries a higher current, but the AC-3 number is the one that decides motor fit. One normally-closed auxiliary contact is built in — enough for a holding circuit or status feedback, but no spare for additional logic without an add-on block. Mounts on DIN rail or plate. The 45 mm width (3-module footprint) fits standard enclosure rail; depth is 80 mm, height 74 mm. That 80 mm depth matters when you're laying out a shallow panel — it's the dimension that hits the gland plate first. ## Standards and environmental limits Certified to EN/IEC 60947-4-1 (contactor standard) and EN/IEC 60947-5-1 (control circuit devices), plus the Chinese GB/T equivalents. Fire resistance tested to 850 °C per IEC 60695-2-1 — that's the glow-wire test for unattended appliances. No derating needed up to 3000 m altitude. Protective treatment TH (pollution degree 3) per IEC 60068-2-30 means it handles humid, corrosive environments typical of industrial panels — think cement plants or textile mills, not clean rooms.","metaTitle":"Schneider LC1E0901E7 Easy TeSys Contactor, 9A AC-3, 48V AC C","metaDescription":"Schneider Electric LC1E0901E7 Easy TeSys Control contactor. 3P (3NO), 9A in AC-3 at ≤440V, 48V AC 50/60Hz coil. 1NC aux. Active production. DIN rail mount. IEC/GB standards.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"80 mm","Range":"Easy TeSys","Width":"45 mm","Height":"74 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"DIN rail Plate","Non-overlap time":"1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"3P","Operating altitude":"3000 m without derating","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068-2-30","Utilisation category":"AC-3 AC-3e AC-1","Contactor application":"Motor control Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)","IP degree of protection":"IP2X conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8f49fce7388df3b4f553e334baf8a51f.pdf","sourceUrl":"https://www.se.com/ae/en/product/LC1E0901E7/contactoreasy-tesys-controllc1e3p3noac3-ac3e440v9a48v-ac-coil50-60hz1nc-auxiliary-contact/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E0901E7/alternatives.json"},"ai":{"faq":[{"question":"What standards does the LC1E0901E7 comply with?","answer":"It complies with EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and the Chinese GB/T 14048 series equivalents. Also tested to EN/IEC 60335-1 Clause 30.2 and EN/IEC 60335-2-40 Annex JJ for appliance applications."},{"question":"What is the mounting option for this contactor?","answer":"It mounts on DIN rail or directly to a plate. The 45 mm width fits standard 3-module DIN-rail spacing."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E0901E7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E0901E7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}