{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E0901U5","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E0901U5","canonicalUrl":"https://aoctrl.com/schneider/LC1E0901U5","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E0901U5","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control, LC1E0901U5, 3-pole contactor, 9 A AC-3 at ≤ 440 V, 240 V AC coil, DIN-rail mount.","salesMarkdown":"The Schneider Electric LC1E0901U5 is a 3-pole (3 NO) contactor from the Easy TeSys Control range, rated 9 A in AC-3 utilisation category at ≤ 440 V, with a 240 V AC coil. That AC-3 rating means it is sized for direct-on-line starting of squirrel-cage motors — the current it makes and breaks is the locked-rotor value, typically 6 to 8 times the motor full-load current, so a 9 A AC-3 contactor handles a motor drawing roughly 1.1 to 1.5 A at full load. The same contactor also carries AC-1 (resistive load) and AC-3e (enhanced motor) ratings, giving flexibility for heater banks or higher-efficiency motor profiles. This is a straightforward pick for panels where the control transformer secondary is 240 V. ## Where it goes and what it survives The 45 mm width (one standard modular unit) fits neatly into a crowded enclosure alongside motor-protection breakers and overload relays. Depth is 80 mm, height 74 mm — shallow enough for shallow backboxes. Storage range is -60 to 80 °C. Fire resistance is 850 °C per IEC 60695-2-1 — a mandatory spec for appliances and equipment that must not propagate flame. IP2X per IEC 60529 means the enclosure protects against fingers (12 mm diameter probe) but not against dust or water ingress. Inside a panel, that is normal — the panel door provides the environmental seal. Certified to EN/IEC 60947-1 (general rules), EN/IEC 60947-4-1 (contactors and motor-starters), EN/IEC 60947-5-1 (control-circuit devices), plus the Chinese GB/T equivalents. Also complies with EN/IEC 60335-1 Clause 30.2 and EN/IEC 60335-2-40 Annex JJ for electrical heat pumps and air-conditioning appliances — relevant if the contactor ends up in a packaged HVAC unit. Mechanical robustness is specified: 1.5 Gn vibration (5-300 Hz) with the contactor open, 3 Gn closed; shock resistance of 7 Gn for 11 ms open, 10 Gn for 11 ms closed. That is enough for most industrial machinery but not for shipboard or off-road equipment — those would typically require a higher shock rating. Altitude rating is 3000 m without derating. Above that, the air density drop reduces dielectric withstand and cooling — if your site is above 3000 m, the contactor still works but the rated operational current must be reduced per IEC 60947-1. For most cement plants, kiln areas sit well below that threshold.","metaTitle":"Schneider Electric LC1E0901U5 Easy TeSys Contactor, 9A AC-3,","metaDescription":"Active-production 3-pole contactor rated 9A AC-3 at ≤440V. 240V AC coil. DIN-rail mount. EN/IEC 60947 certified. Sourced to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"80 mm","Range":"Easy TeSys","Width":"45 mm","Height":"74 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"Plate DIN rail","Non-overlap time":"1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"3P","Operating altitude":"3000 m without derating","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068-2-30","Utilisation category":"AC-3 AC-3e AC-1","Contactor application":"Motor control Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)","IP degree of protection":"IP2X conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$13.41","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/02bdec14167674b9b2625d8e56ac2b51.pdf","sourceUrl":"https://www.se.com/in/en/product/LC1E0901U5/easy-tesys-contactor-3p3-no-ac3-440-v-9a-240-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E0901U5/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings I need to check for fit?","answer":"The critical rating is 9 A in AC-3 at ≤ 440 V for motor switching. The coil is 240 V AC. It is a 3-pole (3 NO) contactor with a 45 mm width and 80 mm depth, DIN-rail mount. Ambient operation is -5 to 55 °C."},{"question":"What standards does this contactor comply with?","answer":"It complies with EN/IEC 60947-1, 60947-4-1, 60947-5-1, the Chinese GB/T 14048 series, and EN/IEC 60335-1 Clause 30.2 and 60335-2-40 Annex JJ for appliance use. Fire resistance is 850 °C per IEC 60695-2-1."},{"question":"What is the mounting and environmental protection?","answer":"Mounts on DIN rail or plate. IP2X per IEC 60529 (finger-safe, not dust/water sealed). Protective treatment TH (pollution degree 3) for humid environments. Storage temperature -60 to 80 °C, operation -5 to 55 °C."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E0901U5","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E0901U5 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}