{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E12004M5WBIN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E12004M5WBIN","canonicalUrl":"https://aoctrl.com/schneider/LC1E12004M5WBIN","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E12004M5WBIN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control contactor, LC1E12004M5WBIN, 4-pole normally open, 32 A AC-1 at 415 V, 220 V AC 50 Hz coil, screw clamp terminals.","salesMarkdown":"The 4 NO pole configuration means all four poles switch together; there are no auxiliary contacts built in, so plan for a separate auxiliary block if your circuit needs feedback or interlocking. Control circuit is 220 V AC 50 Hz, wide-range coil, with a drop-out threshold of 0.3 to 0.6 Uc and pick-up at 0.7 to 1.25 Uc. Inrush power is 95 VA at 50 Hz, cos phi 0.75, which matters for transformer sizing in the control transformer feeding the panel. Screw-clamp terminals on both power and control circuits accept up to 6 mm² solid or 4 mm² flexible with ferrule. Torque to 1.2 N.m on all terminals. IP20 finger-safe protection means it is suitable for enclosed panels only. Protective treatment TH per IEC 60068 for tropical climates.","metaTitle":"Schneider LC1E12004M5WBIN Easy TeSys Contactor, 32 A AC-1, 4","metaDescription":"Schneider Electric LC1E12004M5WBIN Easy TeSys contactor. 32 A rated operational current AC-1 at 415 V, 4-pole normally open, 220 V AC 50 Hz coil. Active production. DIN rail mount.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"80 mm","Range":"Easy TeSys","Width":"45 mm","Height":"74 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5","Operating time":"12...22 ms on closing 4...19 ms on opening","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Heat dissipation":"2...3 W for control circuit","Mounting support":"DIN rail Plate","Pollution degree":"3","Range of product":"Easy TeSys Control","Average impedance":"2.5 mOhm - Ith 32 A 50 Hz for power circuit","Device short name":"LC1E","Poles description":"4P","Tightening torque":"Power circuit: 1.2 N.m Control circuit: 1.2 N.m","Inrush power in VA":"95 VA 50 Hz cos phi 0.75 (at 20 °C)","Operating altitude":"3000 m","Control circuit type":"AC at 50 Hz wide range","Overvoltage category":"III","Protective treatment":"TH conforming to IEC 60068","Utilisation category":"AC-1","Contactor application":"Resistive load","Electrical durability":"300000 cycles AC-1","Mechanical durability":"10000000 cycles","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)","Associated fuse rating":"32 A gG at <= 690 V coordination type 1 for power circuit","Maximum operating rate":"1800 cyc/h 60 °C","Connections - terminals":"Power circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 1...2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1...2.5 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 1...6 mm² - cable stiffness: solid Power circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: solid Control circuit: screw clamp terminals 1 1...6 mm² - cable stiffness: solid Control circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: solid","IP degree of protection":"IP20 conforming to IEC 60529","Rated breaking capacity":"96 A at 440 V for power circuit conforming to IEC 60947","Pole contact composition":"4 NO","Product or component type":"Contactor","Irms rated making capacity":"120 A at 440 V AC for power circuit conforming to IEC 60947-4-1","Power dissipation per pole":"2.6 W AC-1","[Uc] control circuit voltage":"220 V AC 50 Hz","Auxiliary contact composition":"Without","[Ui] rated insulation voltage":"690 V conforming to IEC 60947-4-1","Control circuit voltage limits":"0.3...0.6 Uc (-5...55 °C):drop-out 50 Hz 0.7...1.25 Uc (-5...55 °C):operational 50 Hz","[Ie] rated operational current":"32 A (at <40 °C) at <= 415 V AC AC-1 for power circuit","[Ue] rated operational voltage":"Power circuit: <= 690 V AC 50/60 Hz","Hold-in power consumption in VA":"8.5 VA 50 Hz cos phi 0.27 (at 20 °C)","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947","[Icw] rated short-time withstand current":"105 A 40 °C - 10 s for power circuit 61 A 40 °C - 60 s for power circuit 30 A 40 °C - 600 s for power circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/LC1E12004M5WBIN/easy-tesys-contactor-4p-ctr-45a-ac14no220v-50hz-wb/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E12004M5WBIN/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings I need to check for fit?","answer":"The rated operational current is 32 A in AC-1 category at up to 415 V, 40 °C ambient. The coil is 220 V AC 50 Hz. It has 4 normally-open main poles with no built-in auxiliary contacts. Mounting is 45 mm wide for DIN rail."},{"question":"What compliance documentation is available for this part?","answer":"The contactor is certified to EN/IEC 60947-1, -4-1, and -5-1, plus GB/T equivalents. It carries IP20 protection per IEC 60529 and TH protective treatment per IEC 60068. Fire resistance is tested to 850 °C per IEC 60695-2-1."},{"question":"Can this contactor switch motor loads?","answer":"No — the utilisation category is AC-1, which is rated for resistive loads only. For motor switching (AC-3), a different contactor variant from the Easy TeSys range would be needed."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E12004M5WBIN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E12004M5WBIN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}