{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E12008M5WBIN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E12008M5WBIN","canonicalUrl":"https://aoctrl.com/schneider/LC1E12008M5WBIN","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E12008M5WBIN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control LC1E12008M5WBIN, 4-pole contactor, 32 A AC-1, 220 VAC 50 Hz coil, screw clamp terminals, IP20.","salesMarkdown":"The Schneider Electric LC1E12008M5WBIN is a 4-pole contactor from the Easy TeSys Control range, rated for 32 A in AC-1 utilisation category (resistive load) at up to 415 V AC. That 32 A figure is the current it can carry continuously in a resistive heating or lighting circuit — not a motor-starting rating. The coil is 220 V AC at 50 Hz, with a wide-range control circuit that pulls 95 VA inrush at 20 °C and settles to 2–3 W heat dissipation. It's built to EN/IEC 60947-4-1 and 60947-5-1, so it's certified for both power switching and control-circuit isolation in the same package. The contactor has 2 normally-open and 2 normally-closed power poles — that's a 4-pole configuration common for switching three-phase plus neutral or dual circuits. The auxiliary contact composition is listed as \"without\", so there's no built-in aux block; if you need feedback to a PLC or a seal-in circuit, you'll add a side-mount aux contact separately. The associated fuse recommendation is 32 A gG at ≤ 690 V, coordination type 1, meaning the contactor is protected by that fuse and may need replacement after a short-circuit event. Screw-clamp terminals on both power and control circuits accept solid up to 6 mm² or flexible with ferrule up to 4 mm². Tightening torque is 1.2 N.m for both circuits — a common value, so no special tool needed. IP20 finger-safe front, but the terminals are live when wired — standard panel practice.","metaTitle":"Schneider LC1E12008M5WBIN Easy TeSys Contactor, 32 A AC-1, 2","metaDescription":"Schneider Electric Easy TeSys LC1E12008M5WBIN contactor, 32 A rated operational current (AC-1), 220 VAC 50 Hz coil, 4-pole (2 NO + 2 NC). Active production. Sourced to order. RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"80 mm","Range":"Easy TeSys","Width":"45 mm","Height":"74 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5","Operating time":"12...22 ms on closing 4...19 ms on opening","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Heat dissipation":"2...3 W for control circuit","Mounting support":"DIN rail Plate","Pollution degree":"3","Range of product":"Easy TeSys Control","Average impedance":"2.5 mOhm - Ith 32 A 50 Hz for power circuit","Device short name":"LC1E","Poles description":"4P","Tightening torque":"Power circuit: 1.2 N.m Control circuit: 1.2 N.m","Inrush power in VA":"95 VA 50 Hz cos phi 0.75 (at 20 °C)","Operating altitude":"3000 m","Control circuit type":"AC at 50 Hz wide range","Overvoltage category":"III","Protective treatment":"TH conforming to IEC 60068","Utilisation category":"AC-1","Contactor application":"Resistive load","Electrical durability":"300000 cycles AC-1","Mechanical durability":"10000000 cycles","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)","Associated fuse rating":"32 A gG at <= 690 V coordination type 1 for power circuit","Maximum operating rate":"1800 cyc/h 60 °C","Connections - terminals":"Power circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 1...2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1...2.5 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 1...6 mm² - cable stiffness: solid Power circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: solid Control circuit: screw clamp terminals 1 1...6 mm² - cable stiffness: solid Control circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: solid","IP degree of protection":"IP20 conforming to IEC 60529","Rated breaking capacity":"96 A at 440 V for power circuit conforming to IEC 60947","Pole contact composition":"2 NO + 2 NC","Product or component type":"Contactor","Irms rated making capacity":"120 A at 440 V AC for power circuit conforming to IEC 60947-4-1","Power dissipation per pole":"2.6 W AC-1","[Uc] control circuit voltage":"220 V AC 50 Hz","Auxiliary contact composition":"Without","[Ui] rated insulation voltage":"690 V conforming to IEC 60947-4-1","Control circuit voltage limits":"0.3...0.6 Uc (-5...55 °C):drop-out 50 Hz 0.7...1.25 Uc (-5...55 °C):operational 50 Hz","[Ie] rated operational current":"32 A (at <40 °C) at <= 415 V AC AC-1 for power circuit","[Ue] rated operational voltage":"Power circuit: <= 690 V AC 50/60 Hz","Hold-in power consumption in VA":"8.5 VA 50 Hz cos phi 0.27 (at 20 °C)","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947","[Icw] rated short-time withstand current":"105 A 40 °C - 10 s for power circuit 61 A 40 °C - 60 s for power circuit 30 A 40 °C - 600 s for power circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/LC1E12008M5WBIN/easy-tesys-contactor-4p-ctr-45a-ac12no+2nc220v-50hz-wb/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E12008M5WBIN/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings I need to check for fit?","answer":"The rated operational current is 32 A in AC-1 (resistive load) at ≤ 415 V AC. The coil is 220 V AC 50 Hz. It is a 4-pole contactor with 2 NO + 2 NC power poles and no built-in auxiliary contacts."},{"question":"What standards does this contactor comply with?","answer":"It complies with EN/IEC 60947-1, 60947-4-1, and 60947-5-1, plus the Chinese GB/T equivalents. Overvoltage category III and pollution degree 3 are specified for industrial panel use."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E12008M5WBIN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E12008M5WBIN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}