{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E1201F6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E1201F6","canonicalUrl":"https://aoctrl.com/schneider/LC1E1201F6","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E1201F6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control, LC1E1201F6, 3P(3NO) contactor, AC-3/AC-3e 12A ≤440V, 110V AC coil 60Hz, 1NC auxiliary contact.","salesMarkdown":"The coil is 110 V AC at 60 Hz, and it includes one normally-closed auxiliary contact. The AC-1 rating covers resistive loads like heaters at a higher current, but for motor duty the AC-3 figure is the binding spec. The 1.5 ms non-overlap time between NC and NO contacts ensures the auxiliary circuit breaks before the main poles close, which matters for reversing or star-delta schemes where overlapping could short phases. The coil is 110 V AC at 60 Hz only — not a 50/60 Hz dual-frequency coil. If your control voltage is 110 V at 50 Hz or 220 V at either frequency, this contactor will not pull in reliably. Verify the control transformer matches 110 V 60 Hz before committing the BOM line. A direct parametric substitute would need the same 3-pole, 12 A AC-3, 110 V AC 60 Hz coil, 1NC auxiliary, and DIN-rail footprint — but that is a cross-reference you would need to validate against your panel layout and control voltage. It also meets EN/IEC 60335-1 Clause 30.2 and EN/IEC 60335-2-40 Annex JJ for appliance applications. Ambient temperature range is -20 to 70 °C at the coil, with storage from -60 to 80 °C and operation from -5 to 55 °C. Mechanical robustness is specified for vibration (1.5 Gn open, 3 Gn closed) and shock (7 Gn open, 10 Gn closed) — figures that confirm it holds up on a machine-mounted panel.","metaTitle":"Schneider LC1E1201F6 Easy TeSys Contactor, 12A AC-3, 110V AC","metaDescription":"Obsolete Schneider LC1E1201F6 Easy TeSys Control contactor. 3P(3NO), 12A at 440V AC-3/AC-3e, 110V AC 60Hz coil, 1NC aux. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"80 mm","Range":"Easy TeSys","Width":"45 mm","Height":"74 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"Plate DIN rail","Non-overlap time":"1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"3P","Operating altitude":"3000 m without derating","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068-2-30","Utilisation category":"AC-3 AC-3e AC-1","Contactor application":"Motor control Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)","IP degree of protection":"IP2X conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9521dae01c7397cc1a48da42ca152d9b.pdf","sourceUrl":"https://www.se.com/sg/en/product/LC1E1201F6/contactoreasy-tesys-controllc1e3p3noac3-ac3e440v12a110v-ac-coil60hz1nc-auxiliary-contact/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E1201F6/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to the LC1E1201F6?","answer":"There is no official successor order code from Schneider. A direct replacement would need the same 3-pole, 12 A AC-3 at 440 V, 110 V AC 60 Hz coil, 1NC auxiliary, and DIN-rail mount — but you would need to cross-reference against your specific panel layout and control voltage. The obsolete status means the surplus channel is the practical source."},{"question":"What is the depth of the LC1E1201F6?","answer":"The depth is 80 mm, with a width of 45 mm and height of 74 mm."},{"question":"What compliance documentation is available for the LC1E1201F6?","answer":"The contactor is certified to EN/IEC 60947-1, -4-1, -5-1, and the Chinese GB/T 14048 series. It also meets EN/IEC 60335-1 Clause 30.2 and EN/IEC 60335-2-40 Annex JJ for appliance safety. Fire resistance is tested to 850 °C per IEC 60695-2-1, and protective treatment is TH (pollution degree 3) per IEC 60068-2-30."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E1201F6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E1201F6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}