{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E1201M6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E1201M6","canonicalUrl":"https://aoctrl.com/schneider/LC1E1201M6","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E1201M6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact TVS, 3P contactor, 12A AC-3 at 440V, 220V AC coil, DIN rail mount.","salesMarkdown":"The Schneider Electric LC1E1201M6 is a three-pole EasyPact TVS contactor from the Easy TeSys Control range, rated 12 A in AC-3 duty at up to 440 V — meaning it handles motor switching for small pumps, fans, and conveyors in that current class. The coil is 220 V AC. It mounts on a DIN rail or plate, and the physical footprint is 45 mm wide by 74 mm high by 80 mm deep. It carries approvals under EN/IEC 60947-1, -4-1, and -5-1, plus the corresponding GB/T standards, so it meets the usual panel-building requirements for motor-starting and resistive-load switching. Fire resistance is rated to 850 °C per IEC 60695-2-1, and the protective treatment is TH (pollution degree 3) per IEC 60068-2-30 — fine for standard industrial environments, but not sealed against washdown (IP2X only). The headline AC-3 rating of 12 A at 440 V is the motor-switching current — that is the figure that governs whether this contactor can start and stop a three-phase induction motor without welding the contacts. The same part is also rated AC-1 for resistive loads, where it can carry a higher current, but for motor duty the 12 A limit is the hard stop. The utilisation categories listed are AC-3, AC-3e, and AC-1, so it covers both standard motor starting and the more stringent AC-3e (enhanced electrical endurance) for frequent switching.","metaTitle":"Schneider Electric LC1E1201M6 EasyPact TVS Contactor, 12A AC","metaDescription":"Obsolete Schneider LC1E1201M6 EasyPact TVS contactor. 3P, 12A AC-3 at 440V, 220V AC coil, DIN rail mount. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"80 mm","Range":"Easy TeSys","Width":"45 mm","Height":"74 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"Plate DIN rail","Non-overlap time":"1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"3P","Operating altitude":"3000 m without derating","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068-2-30","Utilisation category":"AC-3 AC-3e AC-1","Contactor application":"Motor control Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)","IP degree of protection":"IP2X conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e7483105b1acbeded384677be5eec1ed.pdf","sourceUrl":"https://www.se.com/id/en/product/LC1E1201M6/easypact-tvs-contactor-3p3-no-ac3-440-v-12a-220-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E1201M6/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings of the LC1E1201M6?","answer":"It is a 3-pole contactor rated 12 A in AC-3 duty at up to 440 V, with a 220 V AC coil. It mounts on a DIN rail or plate, measures 45 x 74 x 80 mm, and complies with EN/IEC 60947-1, -4-1, and -5-1."},{"question":"What standards does the LC1E1201M6 comply with?","answer":"It complies with EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and the corresponding GB/T standards (GB/T 14048.1, GB/T 14048.4, GB/T 14048.5). It also meets the glow-wire test at 850 °C per IEC 60695-2-1 and has TH protective treatment (pollution degree 3) per IEC 60068-2-30."},{"question":"What is the mounting and physical size of the LC1E1201M6?","answer":"It mounts on a DIN rail or plate. Dimensions are 45 mm wide, 74 mm high, and 80 mm deep."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E1201M6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E1201M6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}