{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E1801E5","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E1801E5","canonicalUrl":"https://aoctrl.com/schneider/LC1E1801E5","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E1801E5","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact TVS, LC1E1801E5, 3P contactor, AC-3 18A ≤440V, 48V AC coil, obsolete.","salesMarkdown":"The Schneider Electric LC1E1801E5 is an EasyPact TVS contactor from the Easy TeSys Control range, with 3 poles (3 NO) rated for AC-3 duty at 18 A up to 440 V and a 48 V AC coil. It is designed for motor control and resistive load switching in industrial control panels. The AC-3 rating (18 A at ≤440 V) means it handles the inrush of squirrel-cage motors during starting and breaks the running current — the rating that matters for motor contactor selection. The AC-1 rating covers resistive loads at the same current level. Mounts on a plate or DIN rail, occupying 45 mm width, 74 mm height, and 80 mm depth — a standard footprint for this class of contactor. The IP2X degree of protection means it is finger-safe but not sealed against moisture; install inside an enclosure for washdown or outdoor environments. Operates in ambient temperatures from -5 °C to 55 °C, with storage range of -60 °C to 80 °C. No derating needed up to 3000 m altitude. The TH protective treatment (pollution degree 3) per IEC 60068-2-30 means it withstands humid, tropical conditions — suitable for non-condensing environments in global installations.","metaTitle":"Schneider Electric LC1E1801E5 Contactor, 18A AC-3, 48V AC Co","metaDescription":"Schneider Electric EasyPact TVS contactor LC1E1801E5, 3P, 18A AC-3 at 440V, 48V AC coil. Obsolete. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"80 mm","Range":"Easy TeSys","Width":"45 mm","Height":"74 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"Plate DIN rail","Non-overlap time":"1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"3P","Operating altitude":"3000 m without derating","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068-2-30 test Db","Utilisation category":"AC-3 AC-3e AC-1","Contactor application":"Motor control Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)","IP degree of protection":"IP2X conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3e50554806c1e5a424f06c55c71541c3.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC1E1801E5/easypact-tvs-contactor-3p3-no-ac3-440-v-18a-48-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E1801E5/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for the LC1E1801E5?","answer":"It is a 3-pole contactor rated 18 A in AC-3 duty at ≤440 V, with a 48 V AC coil. It also carries AC-1 and AC-3e utilization categories."},{"question":"What compliance standards does the LC1E1801E5 meet?","answer":"It conforms to EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, GB/T 14048.1, GB/T 14048.4, GB/T 14048.5, and EN/IEC 60335-1 Clause 30.2 and EN/IEC 60335-2-40 Annex JJ. Fire resistance is 850 °C per IEC 60695-2-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E1801E5","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E1801E5 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}