{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E1810B6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E1810B6","canonicalUrl":"https://aoctrl.com/schneider/LC1E1810B6","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E1810B6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control LC1E1810B6, 3-pole contactor, 18 A AC-3/AC-3e at ≤440 V, 24 V AC 60 Hz coil, 1 NO auxiliary contact, obsolete.","salesMarkdown":"The Schneider Electric LC1E1810B6 is a 3-pole contactor from the Easy TeSys Control range, rated 18 A in AC-3 / AC-3e utilisation category at ≤440 V — meaning it switches standard three-phase squirrel-cage motors up to that current during starting and stopping, where the load current during acceleration is typically 5–7× the rated full-load current. The 24 V AC 60 Hz coil draws its control power from a dedicated transformer or control circuit; the 1 NO auxiliary contact provides a feedback or interlock signal without an add-on block. Rated operational voltage is listed for the power circuit; the control circuit is isolated. The 18 A AC-3 rating, 24 V AC 60 Hz coil, 1 NO auxiliary, and DIN-rail footprint must be matched in a substitute. ## Standards and compliance — what the approvals cover It also complies with EN/IEC 60335-1 Clause 30.2 and EN/IEC 60335-2-40 Annex JJ for glow-wire and fire-resistance requirements — relevant if the contactor is used inside a household or commercial appliance. Protective treatment is TH (tropicalised, pollution degree 3) per IEC 60068-2-30, meaning it withstands high humidity and cyclic condensation — suitable for non-condensing environments in warm climates. ## Environmental limits — where it can run Permissible ambient air temperature around the device is -20 to 70 °C at the coil rated voltage (Uc), with storage from -60 to 80 °C, and operation from -5 to 55 °C. The narrower operating range (-5 to 55 °C) is the one that governs real panel conditions — the wider storage range simply means the part can survive shipping and warehouse extremes without damage. Mechanical robustness is specified at 1.5 Gn vibration (5–300 Hz) with contacts closed, and 10 Gn shock for 11 ms with contacts closed.","metaTitle":"Schneider LC1E1810B6 Easy TeSys Contactor, 18A, 24V AC, Obso","metaDescription":"Obsolete Schneider LC1E1810B6 Easy TeSys contactor, 3P, 18A AC-3, 24V AC 60Hz coil, 1NO aux. Sourced to order against RFQ. Standards: EN/IEC 60947.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"80 mm","Range":"Easy TeSys","Width":"45 mm","Height":"74 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"DIN rail Plate","Non-overlap time":"1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"3P","Operating altitude":"3000 m without derating","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068-2-30 test Db","Utilisation category":"AC-3 AC-3e AC-1","Contactor application":"Motor control Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)","IP degree of protection":"IP2X conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6195f0d0e7ece88db04f7ec16014b83e.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC1E1810B6/contactoreasy-tesys-controllc1e3p3noac3-ac3e440v18a24v-ac-coil60hz1no-auxiliary-contact/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E1810B6/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for fit?","answer":"18 A in AC-3 / AC-3e at ≤440 V, 24 V AC 60 Hz coil, 1 NO auxiliary contact, 3-pole, DIN-rail or plate mount, 45 mm width. Standards: EN/IEC 60947-4-1 and -5-1."},{"question":"How do I source this obsolete part?","answer":"Through surplus or broker inventory. We can quote it against an RFQ, but availability is limited and no factory lead time applies."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E1810B6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E1810B6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}