{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E25004B7IN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E25004B7IN","canonicalUrl":"https://aoctrl.com/schneider/LC1E25004B7IN","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E25004B7IN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control, LC1E25004B7IN, 4P(4NO) contactor, AC-1 ≤415 V 50 A, 24 V coil, obsolete.","salesMarkdown":"The LC1E25004B7IN is a 4-pole (4NO) contactor from Schneider Electric's Easy TeSys Control range, rated 50 A in AC-1 utilisation category at ≤415 V with a 24 V coil. AC-1 means it's designed for resistive loads — heaters, lighting banks, non-inductive elements — not motor starting. The 4 NO poles give you four independent switching paths, useful for multi-circuit resistive banks or as a main contactor in a resistive load panel. ## Sourcing reality — this part is obsolete Schneider has marked the LC1E25004B7IN as obsolete. No official successor order code is listed, so the replacement path is not a simple cross-reference. ## Physical fit and integration The contactor measures 56 mm wide by 64 mm high by 93 mm deep, and mounts on either a plate or a DIN rail. At 93 mm depth, it projects further from the rail than a typical compact contactor — factor that into enclosure depth and gland-plate clearance. IP2X protection means the housing is finger-safe but not sealed against dust or moisture; keep it inside an IP54 or better enclosure in any industrial environment. The protective treatment is TH (pollution degree 3) per IEC 60068, so it handles the conductive-dust conditions common in light-industrial panels. ## Standards and compliance footprint Fire resistance is rated to 850 °C per IEC 60695-2-1, so it meets the glow-wire test for unattended equipment. Operating altitude is 3000 m, which covers most high-altitude installations without derating.","metaTitle":"Schneider LC1E25004B7IN Easy TeSys Contactor, 4P 50A AC-1 24","metaDescription":"Obsolete 4-pole contactor, 50 A AC-1 at ≤415 V, 24 V coil. DIN-rail mount, IP2X. Sourced to order — confirm fit before BOM freeze.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"93 mm","Range":"Easy TeSys","Width":"56 mm","Height":"64 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"Plate DIN rail","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"4P","Operating altitude":"3000 m","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068","Utilisation category":"AC-1","Contactor application":"Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor closed (10 Gn for 11 ms) Shocks contactor open (6 Gn for 11 ms)","IP degree of protection":"IP2X conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5a290e25a71f8edb48cac64006416327.pdf","sourceUrl":"https://www.se.com/sg/en/product/LC1E25004B7IN/contactoreasy-tesys-controllc1e4p4noac1415v50a24v/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E25004B7IN/alternatives.json"},"ai":{"faq":[{"question":"What replaces the LC1E25004B7IN?","answer":"No official successor order code is listed. The replacement is not a direct cross-reference — you will need to evaluate a form-fit-function alternative from the current Easy TeSys or TeSys Deca range, or source the original code through surplus channels."},{"question":"What are the key ratings for this contactor?","answer":"4 poles (4NO), AC-1 utilisation category, rated operational voltage ≤415 V, rated current 50 A, coil voltage 24 V. It is designed for resistive loads, not motor starting."},{"question":"What compliance documentation is available?","answer":"The contactor is certified to EN/IEC 60947-1, -4-1, and -5-1, plus Chinese GB/T 14048.1, -4, and -5. Fire resistance is tested to 850 °C per IEC 60695-2-1. Protective treatment is TH (pollution degree 3) per IEC 60068."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E25004B7IN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E25004B7IN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}