{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E25004M5WBIN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E25004M5WBIN","canonicalUrl":"https://aoctrl.com/schneider/LC1E25004M5WBIN","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E25004M5WBIN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control, LC1E25004M5WBIN, 4-pole contactor, 50 A AC-1, 220 V AC 50 Hz coil, screw clamp terminals.","salesMarkdown":"It is rated for 50 A operational current in AC-1 utilisation category at ≤415 V AC, meaning it is sized for resistive load switching — heaters, lighting banks, or other non-inductive circuits where the current waveform stays near sinusoidal. The 220 V AC 50 Hz coil draws 95 VA inrush at 20 °C, with a hold dissipation of 2 to 3 W on the control circuit. The 4 NO pole arrangement gives you four independent switching paths that close together, so one contactor can switch a three-phase resistive load plus a neutral, or four separate single-phase circuits. There are no auxiliary contacts built in — the auxiliary contact composition is listed as without, so any feedback or interlock signals require a separate add-on block. The headline rating is 50 A at ≤415 V AC in AC-1 duty. This is the continuous resistive load the contactor can carry and break. For motor loads (AC-3 category) the rating will be lower — this part is not specified for AC-3, so if you are switching a motor directly, look at the TeSys D or F range instead. The rated breaking capacity is 200 A at 440 V, and the rated making capacity is 250 A at 440 V AC, both per IEC 60947-4-1, which covers the inrush and fault-clearing capability for the power circuit. The control circuit voltage limits are specified: drop-out occurs at 0.3 to 0.6 Uc (66 to 132 V AC) across -5 to 55 °C, and pick-up requires 0.7 to 1.25 Uc (154 to 275 V AC) across the same range. This means the coil will hold in through a moderate brownout but drops out cleanly below about 66 V, preventing contact welding on undervoltage recovery. The operating time is 12 to 22 ms on closing and 4 to 19 ms on opening — tight enough for sequencing in a panel without nuisance overlap. The screw clamp terminals on the power circuit accept 1 to 10 mm² solid or 1 to 6 mm² flexible with cable end; control circuit terminals accept 1 to 4 mm². Tightening torque is 1.5 N·m on power terminals, 1.2 N·m on control. The operating altitude goes to 3000 m without derating, and the overvoltage category III rating suits fixed-installation distribution panels downstream of the main breaker. Fire resistance is 850 °C per IEC 60695-2-1, which is the glow-wire test for flammability — relevant for panel certification in some jurisdictions. It also carries the Chinese GB/T equivalents. The protective treatment is TH conforming to IEC 60068, which is the tropicalisation treatment for heat and humidity resistance — relevant if the panel ships to a coastal or high-humidity site.","metaTitle":"Schneider LC1E25004M5WBIN Easy TeSys Contactor, 50 A AC-1, 4","metaDescription":"Schneider Electric LC1E25004M5WBIN Easy TeSys contactor, 4-pole normally open, rated 50 A AC-1 at ≤415 V. Active production. DIN-rail or plate mount. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"93 mm","Range":"Easy TeSys","Width":"56 mm","Height":"84 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5","Operating time":"12...22 ms on closing 4...19 ms on opening","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Heat dissipation":"2...3 W for control circuit","Mounting support":"DIN rail Plate","Pollution degree":"3","Range of product":"Easy TeSys Control","Average impedance":"2.5 mOhm - Ith 50 A 50 Hz for power circuit","Device short name":"LC1E","Poles description":"4P","Tightening torque":"Control circuit: 1.2 N.m Power circuit: 1.5 N.m","Inrush power in VA":"95 VA 50 Hz cos phi 0.75 (at 20 °C)","Operating altitude":"3000 m","Control circuit type":"AC at 50 Hz wide range","Overvoltage category":"III","Protective treatment":"TH conforming to IEC 60068","Utilisation category":"AC-1","Contactor application":"Resistive load","Electrical durability":"350000 cycles AC-1","Mechanical durability":"10000000 cycles","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor closed (10 Gn for 11 ms) Shocks contactor open (6 Gn for 11 ms)","Associated fuse rating":"50 A gG at <= 690 V coordination type 1 for power circuit","Maximum operating rate":"1800 cyc/h 60 °C","Connections - terminals":"Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1...2.5 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 1...10 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 1...6 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: solid Control circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: solid Power circuit: screw clamp terminals 1 1.5...10 mm² - cable stiffness: solid Power circuit: screw clamp terminals 2 1.5...10 mm² - cable stiffness: solid","IP degree of protection":"IP20 conforming to IEC 60529","Rated breaking capacity":"200 A at 440 V for power circuit conforming to IEC 60947","Pole contact composition":"4 NO","Product or component type":"Contactor","Irms rated making capacity":"250 A at 440 V AC for power circuit conforming to IEC 60947-4-1","Power dissipation per pole":"3.2 W AC-1","[Uc] control circuit voltage":"220 V AC 50 Hz","Auxiliary contact composition":"Without","[Ui] rated insulation voltage":"690 V conforming to IEC 60947-4-1","Control circuit voltage limits":"0.3...0.6 Uc (-5...55 °C):drop-out 50 Hz 0.7...1.25 Uc (-5...55 °C):operational 50 Hz","[Ie] rated operational current":"50 A (at <40 °C) at <= 415 V AC AC-1 for power circuit","[Ue] rated operational voltage":"Power circuit: <= 690 V AC 50/60 Hz","Hold-in power consumption in VA":"8.5 VA 50 Hz cos phi 0.3 (at 20 °C)","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947","[Icw] rated short-time withstand current":"240 A 40 °C - 10 s for power circuit 120 A 40 °C - 60 s for power circuit 50 A 40 °C - 600 s for power circuit","[Ith] conventional free air thermal current":"50 A (at 40 °C) for power circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/LC1E25004M5WBIN/easy-tesys-contactor-4p-ctr-100a-ac14no220v-50hz-wb/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E25004M5WBIN/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this contactor?","answer":"Rated operational current is 50 A in AC-1 (resistive load) at ≤415 V AC. The coil is 220 V AC 50 Hz. It has 4 normally open poles and no built-in auxiliary contacts. Mechanical durability is 10 million cycles; electrical durability is 350,000 cycles in AC-1."},{"question":"What compliance standards does this part meet?","answer":"It is certified to EN/IEC 60947-1, EN/IEC 60947-4-1, and EN/IEC 60947-5-1, plus the Chinese GB/T equivalents. The protective treatment is TH per IEC 60068 for tropical environments."},{"question":"What is the mounting and wiring requirement?","answer":"Mounts on DIN rail or plate. Dimensions are 84 x 56 x 93 mm. Power terminals accept 1 to 10 mm² solid or 1 to 6 mm² flexible; control terminals accept 1 to 4 mm². Tightening torque is 1.5 N·m power, 1.2 N·m control."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E25004M5WBIN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E25004M5WBIN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}