{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E25004M7IN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E25004M7IN","canonicalUrl":"https://aoctrl.com/schneider/LC1E25004M7IN","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E25004M7IN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control, LC1E25004M7IN, 4P(4NO) contactor, AC-1 ≤415V 50A, 220V coil.","salesMarkdown":"The LC1E25004M7IN is a 4-pole contactor from Schneider Electric's Easy TeSys Control range, designed for resistive load switching under AC-1 utilisation category. It's rated for 50 A at up to 415 V, making it a fit for heater banks, lighting circuits, or other non-inductive loads in a control panel. Mounts on DIN rail or a backplate, with a compact footprint of 56 mm wide by 64 mm tall by 93 mm deep — sized for a standard enclosure without crowding adjacent devices. The IP2X finger-protection rating means the contactor's live parts are shielded against accidental contact during panel access, which is the minimum expected for enclosed industrial gear. The AC-1 utilisation category is the key spec here: it governs resistive loads where inrush is minimal. At 50 A and 415 V, this contactor handles steady-state heater or resistor bank current without the derating needed for motor (AC-3) duty. If your application is inductive — motors, transformers — this part is not the right choice; you'd need an AC-3 or AC-4 rated contactor instead. Compliance with EN/IEC 60947-4-1 (contactors and motor-starters) and GB/T 14048.4 (Chinese national standard) covers most industrial installations globally, including CE-marked panels and projects requiring Chinese CCC certification.","metaTitle":"Schneider LC1E25004M7IN Easy TeSys Contactor, 4P, AC-1 50A","metaDescription":"Obsolete LC1E25004M7IN contactor from Schneider Electric's Easy TeSys Control range. 4-pole, AC-1 rated 50A at 415V for resistive loads. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"93 mm","Range":"Easy TeSys","Width":"56 mm","Height":"64 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"DIN rail Plate","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"4P","Operating altitude":"3000 m","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068","Utilisation category":"AC-1","Contactor application":"Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor closed (10 Gn for 11 ms) Shocks contactor open (6 Gn for 11 ms)","IP degree of protection":"IP2X conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/80724336b6f292af9b134b0ae0828fcf.pdf","sourceUrl":"https://www.se.com/sg/en/product/LC1E25004M7IN/contactoreasy-tesys-controllc1e4p4noac1415v50a220v/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E25004M7IN/alternatives.json"},"ai":{"faq":[{"question":"What replaces the LC1E25004M7IN?","answer":"No official successor order code is listed in the available records. A replacement would need to be selected based on the original AC-1 rating (50 A at 415 V) and coil voltage (220 V) from the current Easy TeSys or TeSys Deca range, but pin-compatibility and footprint should be verified."},{"question":"What are the key ratings of this contactor?","answer":"It is a 4-pole (4NO) contactor rated for AC-1 resistive loads at 50 A, up to 415 V, with a 220 V coil. It mounts on DIN rail or plate and measures 56 x 64 x 93 mm."},{"question":"What standards does the LC1E25004M7IN comply with?","answer":"It complies with EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and the Chinese equivalents GB/T 14048.1, GB/T 14048.4, and GB/T 14048.5. It also has 850 °C glow-wire fire resistance per IEC 60695-2-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E25004M7IN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E25004M7IN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}