{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E25004N7IN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E25004N7IN","canonicalUrl":"https://aoctrl.com/schneider/LC1E25004N7IN","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E25004N7IN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control, LC1E25004N7IN, 4P (4NO) contactor, AC-1 50A at 415V, DIN rail/plate mount.","salesMarkdown":"The Schneider Electric LC1E25004N7IN is a 4-pole (4NO) contactor from the Easy TeSys Control range, rated for AC-1 utilisation category at 50 A up to 415 V. AC-1 means it's designed for resistive loads — heaters, lighting banks, or other non-inductive circuits — not for motor starting. The 4 normally-open poles give you four independent switching channels in one compact body. The supply is not on the shelf; it's a locate-and-quote process through our multi-source network. Plan for a longer lead time than an active part would carry. The headline rating is AC-1 50 A at 415 V. That's the resistive load rating — it tells you the contactor can carry and break 50 A of steady-state current in a resistive circuit. Don't use this for motor loads (AC-3) or inductive switching; the contactor isn't rated for those duty cycles. The 4-pole configuration gives you four NO contacts, each rated for the full 50 A in AC-1. That covers it for industrial control panels in most global markets. The 850 °C glow-wire test per IEC 60695-2-1 means the plastic body won't propagate a fire under fault conditions — a requirement for panel certification in many jurisdictions. Mechanical robustness is specified: 1.5 Gn vibration when open, 3 Gn when closed, and shock ratings of 6 Gn open / 10 Gn closed. That's adequate for most fixed industrial installations but not for mobile equipment or high-vibration environments like crushers or presses. The 56 mm width and 93 mm depth fit a standard DIN-rail slot. Plate mounting is also supported if your panel uses a backplate layout. The 64 mm height leaves clearance for wiring ducts above and below. For a 4-pole contactor at this current level, the footprint is compact — useful when you're packing multiple contactors into a control panel.","metaTitle":"Schneider Electric LC1E25004N7IN Easy TeSys Contactor, 4P, A","metaDescription":"Obsolete Schneider LC1E25004N7IN Easy TeSys Control contactor. 4P (4NO), AC-1 50A at 415V. Sourced to order against RFQ. DIN rail/plate mount.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"93 mm","Range":"Easy TeSys","Width":"56 mm","Height":"64 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"DIN rail Plate","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"4P","Operating altitude":"3000 m","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068","Utilisation category":"AC-1","Contactor application":"Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor closed (10 Gn for 11 ms) Shocks contactor open (6 Gn for 11 ms)","IP degree of protection":"IP2X conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/09f2c13d08f4f0f1bc51e81c09fca81c.pdf","sourceUrl":"https://www.se.com/sg/en/product/LC1E25004N7IN/contactoreasy-tesys-controllc1e4p4noac1415v50a415v/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E25004N7IN/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for the LC1E25004N7IN?","answer":"It is a 4-pole (4NO) contactor rated AC-1 at 50 A up to 415 V, designed for resistive loads. It mounts on DIN rail or plate, measures 56 x 64 x 93 mm, and operates from -5 to 55 °C."},{"question":"What standards does the LC1E25004N7IN comply with?","answer":"It complies with EN/IEC 60947-1, 60947-4-1, and 60947-5-1, plus the Chinese GB/T 14048.1, 14048.4, and 14048.5. It also passes the 850 °C glow-wire test per IEC 60695-2-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E25004N7IN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E25004N7IN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}