{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E2501F7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E2501F7","canonicalUrl":"https://aoctrl.com/schneider/LC1E2501F7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E2501F7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control, LC1E2501F7, 3-pole contactor, 25 A AC-3/AC-3e at ≤440 V, 110 V AC 50/60 Hz coil, 1 NC auxiliary contact.","salesMarkdown":"The Schneider Electric LC1E2501F7 is a 3-pole contactor from the Easy TeSys Control range, rated 25 A in AC-3 and AC-3e utilisation categories at voltages up to 440 V. The AC-3 rating of 25 A is the motor-switching current — this contactor handles starting and stopping of squirrel-cage motors up to that full-load current without welding or excessive wear. The AC-3e rating extends that to energy-efficient IE3/IE4 motors, which have higher inrush. AC-1 (resistive) duty is also covered for heater or lighting loads. The 1.5 ms non-overlap time between NC and NO contacts is guaranteed on both energisation and de-energisation, which matters for safety circuits where a make-before-break fault could cause a short. The 45 mm width keeps the footprint tight in multi-contactor assemblies. Operating altitude is 3000 m without derating, so it works in high-altitude installations without oversizing. Fire resistance tested to 850 °C per IEC 60695-2-1. Protective treatment TH (pollution degree 3) per IEC 60068-2-30 means it handles humid, mildly corrosive environments typical of food-and-bev or textile plants. Mechanical robustness: the contactor withstands 3 Gn vibration when closed and 10 Gn shocks for 11 ms — enough for machine-mounted applications near presses or conveyors. IP2X finger protection on the front face.","metaTitle":"Schneider LC1E2501F7 Easy TeSys Contactor, 25A AC-3, 110VAC","metaDescription":"Schneider Electric LC1E2501F7 Easy TeSys Control contactor. 3-pole, 25A AC-3/AC-3e at ≤440V, 110VAC 50/60Hz coil, 1NC aux. Active lifecycle. DIN rail or plate mount. EN/IEC 60947 c","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"85 mm","Range":"Easy TeSys","Width":"45 mm","Height":"74 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"DIN rail Plate","Non-overlap time":"1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"3P","Operating altitude":"3000 m without derating","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068-2-30 test Db","Utilisation category":"AC-3 AC-3e AC-1","Contactor application":"Motor control Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor closed (10 Gn for 11 ms) Shocks contactor open (6 Gn for 11 ms)","IP degree of protection":"IP2X conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/90949bf20e007a4166617c3a4932085a.pdf","sourceUrl":"https://www.se.com/ae/en/product/LC1E2501F7/contactoreasy-tesys-controllc1e3p3noac3-ac3e440v25a110v-ac-coil50-60hz1nc-auxiliary-contact/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E2501F7/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this contactor?","answer":"25 A in AC-3/AC-3e at ≤440 V, with a 110 V AC 50/60 Hz coil. It has 3 main poles (3NO) and 1 NC auxiliary contact. The non-overlap time between NC and NO contacts is 1.5 ms guaranteed on both energisation and de-energisation."},{"question":"What standards does the LC1E2501F7 comply with?","answer":"It complies with EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and the Chinese GB/T 14048 series. Fire resistance is tested to 850 °C per IEC 60695-2-1. Protective treatment TH (pollution degree 3) per IEC 60068-2-30 covers humid environments."},{"question":"How is the LC1E2501F7 mounted?","answer":"It mounts on DIN rail or directly to a mounting plate. The 45 mm width fits standard DIN-rail spacing for multi-contactor assemblies."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E2501F7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E2501F7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}