{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E2501U5","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E2501U5","canonicalUrl":"https://aoctrl.com/schneider/LC1E2501U5","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E2501U5","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact TVS contactor, 3P (3 NO), AC-3 ≤ 440 V 25 A, 240 V AC coil, Easy TeSys Control series.","salesMarkdown":"The Schneider Electric LC1E2501U5 is a three-pole contactor from the EasyPact TVS range, part of the Easy TeSys Control series. It is designed for motor control and resistive load switching, rated for AC-3, AC-3e, and AC-1 utilisation categories. The headline rating is 25 A in AC-3 duty at up to 440 V, meaning it can switch three-phase induction motors of that current class — typical for a 7.5 kW motor at 400 V. The 240 V AC coil suits standard control voltage supplies in many regions. The AC-3 rating of 25 A at ≤440 V is the one that governs motor duty; if your load is purely resistive, the AC-1 rating will be higher, but the AC-3 figure is the one to match to your motor FLA. That means it meets the required making/breaking capacity and overload co-ordination for industrial motor circuits. The non-overlap time of 1.5 ms on both energisation and de-energisation is guaranteed between NC and NO contacts. This prevents momentary short-circuits in reversing or star-delta circuits where both contactors could otherwise overlap. For continuous operation, keep ambient below 55 °C. ## Where it goes in the panel IP2X protection means it is touch-safe on the front but not sealed against dust or moisture — install inside a panel with a door, not in a washdown zone. The TH protective treatment (pollution degree 3) confirms it is suitable for controlled industrial environments.","metaTitle":"Schneider LC1E2501U5 EasyPact TVS Contactor, 25A AC-3, 240V","metaDescription":"Schneider LC1E2501U5 EasyPact TVS contactor, 3-pole, 25A AC-3 at ≤440V, 240V AC coil. Active production. Sourced to order. RFQ for pricing.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"85 mm","Range":"Easy TeSys","Width":"45 mm","Height":"74 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"DIN rail Plate","Non-overlap time":"1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"3P","Operating altitude":"3000 m without derating","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068-2-30 test Db","Utilisation category":"AC-3 AC-3e AC-1","Contactor application":"Motor control Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor closed (10 Gn for 11 ms) Shocks contactor open (6 Gn for 11 ms)","IP degree of protection":"IP2X conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$24.01","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c3e7c996d8731b4cd4c70bf373c069c9.pdf","sourceUrl":"https://www.se.com/ae/en/product/LC1E2501U5/easypact-tvs-contactor-3p3-no-ac3-440-v-25a-240-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E2501U5/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for the LC1E2501U5?","answer":"It is a 3-pole contactor rated 25 A in AC-3 duty at ≤440 V, with a 240 V AC coil. It covers AC-3e and AC-1 categories as well. The non-overlap time between NC and NO contacts is 1.5 ms."},{"question":"What standards does the LC1E2501U5 comply with?","answer":"It complies with EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and the corresponding GB/T standards. It also meets fire-resistance requirements at 850 °C per IEC 60695-2-1."},{"question":"How is the LC1E2501U5 mounted?","answer":"It mounts on DIN rail or directly to a mounting plate. The dimensions are 45 mm wide, 74 mm high, and 85 mm deep."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E2501U5","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E2501U5 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}