{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E250M7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E250M7","canonicalUrl":"https://aoctrl.com/schneider/LC1E250M7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E250M7","rawCanonicalId":null},"summary":{"shortDescription":"Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3/AC-3e,<=440V,250A/190A,220V AC coil,50/60Hz","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"181 mm","Range":"Easy TeSys","Width":"168.5 mm","Height":"197 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 GB/T 14048.1 GB/T 14048.4","Motor power kW":"75 kW at 220/230 V AC 50/60 Hz 132 kW at 380/400 V AC 50/60 Hz 140 kW at 415/440 V AC 50/60 Hz 160 kW at 500 V AC 50/60 Hz 160 kW at 660/690 V AC 50/60 Hz 160 kW at 660...690 V AC 50/60 Hz","Operating time":"20...35 ms on closing 130 ms on opening","Product weight":"4.7 kg","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Heat dissipation":"8...9.8 W","Mounting support":"Plate","Pollution degree":"3","Range of product":"Easy TeSys Control","Average impedance":"0.32 mOhm - Ith 300 A 50 Hz for power circuit","Device short name":"LC1E","Poles description":"3P","Tightening torque":"Power circuit: 35 N.m Control circuit: 1.2 N.m","Inrush power in VA":"950...1180 VA 40...400 Hz (at 20 °C)","Operating altitude":"3000 m without derating","Control circuit type":"AC at 50/60 Hz standard","Overvoltage category":"III","Utilisation category":"AC-3 AC-3e AC-1","Contactor application":"Motor control Resistive load","Electrical durability":"700000 cycles AC-3 200000 cycles AC-1","Mechanical durability":"5000000 cycles","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms)","Associated fuse rating":"315 A gG at <= 690 V coordination type 1 for power circuit","Maximum operating rate":"1200 cyc/h 55 °C","Connections - terminals":"Power circuit: cable with lug 2 - external diameter: 185 mm - busbar cross section: 32 x 4 mm Power circuit: bars 2 - external diameter: 185 mm - busbar cross section: 32 x 4 mm Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1...2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1...2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: solid without cable end","IP degree of protection":"IP00 conforming to IEC 60529","Rated breaking capacity":"2000 A at 440 V for power circuit conforming to IEC 60947","Pole contact composition":"3 NO","Product or component type":"Contactor","Irms rated making capacity":"2500 A at 440 V AC for power circuit conforming to IEC 60947-4-1","Power dissipation per pole":"20 W AC-3 29 W AC-1","[Uc] control circuit voltage":"220 V AC 50/60 Hz","Auxiliary contact composition":"Without","[Ui] rated insulation voltage":"690 V conforming to IEC 60947-4-1","Control circuit voltage limits":"0.85...1.1 Uc (-5...55 °C):operational 50/60 Hz 0.35...0.55 Uc (-5...55 °C):drop-out 50/60 Hz","[Ie] rated operational current":"250 A (at 190 A (at 300 A (at <40 °C) at <= 440 V AC AC-1 for power circuit","[Ue] rated operational voltage":"Power circuit: <= 690 V AC 50/60 Hz","Hold-in power consumption in VA":"8.9...10.9 VA 40...400 Hz (at 20 °C)","[Uimp] rated impulse withstand voltage":"8 kV coil not connected to the power circuit conforming to IEC 60947","[Icw] rated short-time withstand current":"1800 A 40 °C - 10 s for power circuit","[Ith] conventional free air thermal current":"300 A (at 40 °C) for power circuit","Permissible ambient air temperature around the device":"-5...55 °C operation -20...70 °C at Uc -60...80 °C storage"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/sg/en/product/LC1E250M7/contactoreasy-tesys-controllc1e3p3noac3-ac3e440v250a-190a220v-ac-coil50-60hz/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E250M7/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E250M7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E250M7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}