{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E250N5","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E250N5","canonicalUrl":"https://aoctrl.com/schneider/LC1E250N5","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E250N5","rawCanonicalId":null},"summary":{"shortDescription":"contactor - EasyPact TVS - 3P (3 NO) - AC-3 - <= 440 V 250 A - 415 V AC coil","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"181 mm","Range":"Easy TeSys","Width":"168.5 mm","Height":"197 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 GB/T 14048.1 GB/T 14048.4","Motor power kW":"75 kW at 220/230 V AC 50/60 Hz 132 kW at 380/400 V AC 140 kW at 415/440 V AC 160 kW at 500 V AC 160 kW at 660/690 V AC 160 kW at 660...690 V","Operating time":"20...35 ms on closing 7...15 ms on opening","Product weight":"4.7 kg","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Heat dissipation":"18...24 W for control circuit","Mounting support":"Plate","Pollution degree":"3","Range of product":"Easy TeSys Control","Average impedance":"0.32 mOhm - Ith 300 A 50 Hz for power circuit","Device short name":"LC1E","Poles description":"3P","Tightening torque":"Control circuit: 1.2 N.m Power circuit: 35 N.m","Inrush power in VA":"805 VA 50 Hz cos phi 0.3 (at 20 °C) 970 VA 60 Hz cos phi 0.3 (at 20 °C)","Operating altitude":"3000 m without derating","Control circuit type":"AC at 50 Hz","Overvoltage category":"III","Utilisation category":"AC-3 AC-3e AC-1","Contactor application":"Motor control Resistive load","Electrical durability":"200000 cycles AC-1 700000 cycles AC-3","Mechanical durability":"5000000 cycles","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms)","Associated fuse rating":"315 A gG at <= 690 V coordination type 1 for power circuit","Maximum operating rate":"1200 cyc/h 55 °C","Connections - terminals":"Power circuit: cable with lug 1 1...4 mm² - external diameter: 185 mm - cable stiffness: flexible without cable end Power circuit: bars 2 1...4 mm² - cable stiffness: flexible without cable end - busbar cross section: 32 x 4 mm Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1...2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1...2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1...4 mm² - external diameter: 185 mm - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: solid without cable end - busbar cross section: 32 x 4 mm","IP degree of protection":"IP00 conforming to IEC 60529","Rated breaking capacity":"2000 A at 440 V for power circuit conforming to IEC 60947","Pole contact composition":"3 NO","Product or component type":"Contactor","Irms rated making capacity":"2500 A at 440 V AC for power circuit conforming to IEC 60947-4-1","Power dissipation per pole":"20 W AC-3 29 W AC-1","[Uc] control circuit voltage":"415 V AC 50 Hz","Auxiliary contact composition":"Without","[Ui] rated insulation voltage":"690 V conforming to IEC 60947-4-1","Control circuit voltage limits":"0.85...1.1 Uc (-5...55 °C):operational 50 Hz 0.35...0.55 Uc (-5...55 °C):drop-out 50 Hz","[Ie] rated operational current":"250 A (at 190 A (at 300 A (at <40 °C) at <= 440 V AC AC-1 for power circuit","[Ue] rated operational voltage":"Power circuit: <= 690 V AC 50/60 Hz","Hold-in power consumption in VA":"55 VA 50 Hz cos phi 0.3 (at 20 °C) 66 VA 60 Hz cos phi 0.3 (at 20 °C)","[Uimp] rated impulse withstand voltage":"8 kV coil not connected to the power circuit conforming to IEC 60947","[Icw] rated short-time withstand current":"1800 A 40 °C - 10 s for power circuit","[Ith] conventional free air thermal current":"300 A (at 40 °C) for power circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$24.01","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ae/en/product/LC1E250N5/contactor-easypact-tvs-3p-3-no-ac3-440-v-250-a-415-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E250N5/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E250N5","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E250N5 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}