{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E2510E5","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E2510E5","canonicalUrl":"https://aoctrl.com/schneider/LC1E2510E5","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E2510E5","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys EasyPact TVS contactor, 3P (3 NO), AC-3 ≤440 V 25 A, 48 V AC coil, DIN rail mount.","salesMarkdown":"The Schneider Electric LC1E2510E5 is a 3-pole EasyPact TVS contactor from the Easy TeSys Control range, rated for 25 A in AC-3 utilisation category at up to 440 V, with a 48 V AC coil. It is designed for motor control and resistive load switching in industrial control panels. The AC-3 rating means it handles starting and stopping of squirrel-cage motors — the 25 A figure governs the motor full-load current it can switch, not the resistive load. For resistive loads (AC-1), the rating is higher, but the AC-3 number is the one that decides fit for motor duty. It also meets GB/T 14048.1, 14048.4, and 14048.5 for the Chinese market, and EN/IEC 60335-1 Clause 30.2 and EN/IEC 60335-2-40 Annex JJ for appliance and HVAC applications. Fire resistance is tested to 850 °C per IEC 60695-2-1. Protective treatment is TH (pollution degree 3) per IEC 60068-2-30, meaning it withstands humid, tropical environments. Mounts on DIN rail or plate, with dimensions 45 mm wide, 74 mm high, and 85 mm deep. The non-overlap time between NC and NO contacts is 1.5 ms on both energisation and de-energisation — this matters for interlocking circuits where a break-before-make sequence is required to prevent shoot-through.","metaTitle":"Schneider LC1E2510E5 EasyPact TVS Contactor, 25A AC-3, 48V A","metaDescription":"Obsolete 3P contactor, 25A AC-3 ≤440V, 48V AC coil. EN/IEC 60947 compliant. DIN rail mount. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"85 mm","Range":"Easy TeSys","Width":"45 mm","Height":"74 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"DIN rail Plate","Non-overlap time":"1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"3P","Operating altitude":"3000 m without derating","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068-2-30 test Db","Utilisation category":"AC-3 AC-3e AC-1","Contactor application":"Motor control Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor closed (10 Gn for 11 ms) Shocks contactor open (6 Gn for 11 ms)","IP degree of protection":"IP2X conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5226ec9a4242ad2826440b21b1fa7784.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC1E2510E5/easypact-tvs-contactor-3p3-no-ac3-440-v-25a-48-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E2510E5/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this contactor?","answer":"It is a 3-pole contactor rated 25 A in AC-3 (motor duty) at up to 440 V, with a 48 V AC coil. It also covers AC-3e and AC-1 utilisation categories. The coil operates at 48 V AC, and the contactor is rated for 3000 m altitude without derating."},{"question":"What compliance documentation is available for this part?","answer":"The contactor carries certifications to EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and the GB/T 14048 series for China. It also meets EN/IEC 60335-1 and 60335-2-40 for appliance/HVAC use. Fire resistance is 850 °C per IEC 60695-2-1."},{"question":"How does this mount in a panel?","answer":"It mounts on DIN rail or a plate. The footprint is 45 mm wide by 74 mm high by 85 mm deep, which is a standard 2.5-module DIN-rail width. IP2X protection means it is suitable for enclosed panel use."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E2510E5","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E2510E5 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}