{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E2510F5","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E2510F5","canonicalUrl":"https://aoctrl.com/schneider/LC1E2510F5","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E2510F5","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys LC1E2510F5, 3-pole contactor, 25 A AC-3 at ≤440 V, 110 V AC coil, DIN-rail or plate mount.","salesMarkdown":"The Schneider Electric Easy TeSys LC1E2510F5 is a 3-pole contactor rated for 25 A in AC-3 utilisation category at ≤440 V, with a 110 V AC coil. AC-3 is the standard duty for squirrel-cage motor starting — switching inductive loads during start-up and disconnecting under running conditions. The same contactor also carries AC-3e (enhanced electrical endurance for motor applications) and AC-1 (resistive load) ratings, so it can handle resistive heater banks or lighting circuits at a higher current if the application needs it. For resistive loads (AC-1), the current capability is higher, but the datasheet doesn't give a separate figure here. The 110 V AC coil is standard for North American control circuits at 110-120 V; verify your control transformer matches. Operates from -5 °C to 55 °C ambient, stores from -60 °C to 80 °C. Vibration resistance: 1.5 Gn open, 3 Gn closed (5-300 Hz); shock: 6 Gn open, 10 Gn closed (11 ms). That's enough for most industrial machinery but not extreme mobile equipment. Compliant with EN/IEC 60947-1, -4-1, -5-1, and the corresponding GB/T standards for the Chinese market. Also listed for EN/IEC 60335-1 Clause 30.2 and -2-40 Annex JJ, which covers glow-wire and fire resistance for household appliances — relevant if this contactor ends up in a packaged HVAC or refrigeration unit.","metaTitle":"Schneider Easy TeSys LC1E2510F5 Contactor, 25A AC-3, 110V AC","metaDescription":"Schneider Easy TeSys LC1E2510F5 contactor, 3-pole, 25A AC-3 at ≤440V, 110V AC coil. Active production. DIN-rail or plate mount. EN/IEC 60947 compliant.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"85 mm","Range":"Easy TeSys","Width":"45 mm","Height":"74 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"DIN rail Plate","Non-overlap time":"1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"3P","Operating altitude":"3000 m without derating","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068-2-30 test Db","Utilisation category":"AC-3 AC-3e AC-1","Contactor application":"Motor control Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor closed (10 Gn for 11 ms) Shocks contactor open (6 Gn for 11 ms)","IP degree of protection":"IP2X conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e518bf6af0d4e36b519a71941470d5b3.pdf","sourceUrl":"https://www.se.com/in/en/product/LC1E2510F5/easy-tesys-contactor-3p3-no-ac3-440-v-25a-110-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E2510F5/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this contactor?","answer":"25 A in AC-3 at ≤440 V, 110 V AC coil, 3-pole (3 NO). Also rated for AC-3e and AC-1 utilisation categories. Dimensions: 45 mm wide, 74 mm high, 85 mm deep."},{"question":"What mounting options does it support?","answer":"DIN rail or plate mounting. IP2X finger protection. No special adapter needed."},{"question":"What standards does it comply with?","answer":"EN/IEC 60947-1, -4-1, -5-1; GB/T 14048.1.4.5; EN/IEC 60335-1 Clause 30.2 and -2-40 Annex JJ. Fire resistance 850 °C per IEC 60695-2-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E2510F5","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E2510F5 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}