{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E2510Q6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E2510Q6","canonicalUrl":"https://aoctrl.com/schneider/LC1E2510Q6","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E2510Q6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control, LC1E2510Q6, 3P(3NO) contactor, AC-3/AC-3e ≤440V 25A, 380V AC coil 60Hz, 1NO auxiliary contact.","salesMarkdown":"It complies with EN/IEC 60947-1, 60947-4-1, and 60947-5-1, plus the Chinese GB/T equivalents — the 60947-4-1 standard specifically covers contactors and motor-starters, so this part is certified for the motor control role it is rated for. ## Sourcing reality — obsolete, sourced to order Because the Easy TeSys Control range is a predecessor to the current TeSys D and TeSys Deca families, an official cross-reference to a current order code is not published in the available lifecycle data. A buyer holding this on a BOM should verify the mounting footprint and coil voltage against a TeSys D equivalent before committing a replacement. ## Integration notes for panel builders At 45 mm wide and 85 mm deep, the LC1E2510Q6 occupies one standard modular slot on a DIN rail. The 74 mm height leaves clearance under a 100 mm enclosure lid. The IP2X finger-safe front face means it can sit in a panel without additional shrouding for basic touch protection. The contactor includes a guaranteed non-overlap time of 1.5 ms between NC and NO contacts on both energisation and de-energisation — this prevents a momentary short-circuit when switching between contactor pairs in reversing or star-delta starters.","metaTitle":"Schneider Electric LC1E2510Q6 Easy TeSys Contactor, 25A AC-3","metaDescription":"Obsolete Schneider Electric LC1E2510Q6 Easy TeSys contactor. 3P, 25A AC-3/AC-3e, 380V AC 60Hz coil, 1NO aux. Sourced to order against RFQ. EN/IEC 60947 certified.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"85 mm","Range":"Easy TeSys","Width":"45 mm","Height":"74 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"Plate DIN rail","Non-overlap time":"1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"3P","Operating altitude":"3000 m without derating","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068-2-30 test Db","Utilisation category":"AC-3 AC-3e AC-1","Contactor application":"Motor control Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor closed (10 Gn for 11 ms) Shocks contactor open (6 Gn for 11 ms)","IP degree of protection":"IP2X conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a16a59523d420d8cff82955f5ce1e4a4.pdf","sourceUrl":"https://www.se.com/eg/en/product/LC1E2510Q6/contactoreasy-tesys-controllc1e3p3noac3-ac3e440v25a380v-ac-coil60hz1no-auxiliary-contact/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E2510Q6/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings of the LC1E2510Q6?","answer":"The contactor is rated 25 A in AC-3 and AC-3e duty at up to 440 V, with a 380 V AC 60 Hz coil. It has three power poles (3NO) and one normally-open auxiliary contact."},{"question":"What standards does the LC1E2510Q6 comply with?","answer":"It complies with EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and the Chinese GB/T 14048 series. The fire resistance is tested to 850 °C per IEC 60695-2-1."},{"question":"How do I source this obsolete part?","answer":"The LC1E2510Q6 is sourced to order against an RFQ through surplus and independent distributor channels. Submit an RFQ for current availability and pricing."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E2510Q6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E2510Q6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}