{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E32004V7IN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E32004V7IN","canonicalUrl":"https://aoctrl.com/schneider/LC1E32004V7IN","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E32004V7IN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control, contactor, LC1E32004V7IN, 4P (4NO), AC-1 ≤415V 55A, 400V coil.","salesMarkdown":"The Schneider Electric LC1E32004V7IN is a 4-pole contactor from the Easy TeSys Control range, rated for AC-1 utilisation category at 55 A on power circuits up to 415 V. AC-1 covers resistive loads — heaters, lighting banks, non-inductive elements — where the switching current and load current are essentially the same. The 4 NO (normally open) pole configuration gives you four independently switched power paths in a single 56 mm wide package that mounts on DIN rail or a plate. The headline 55 A at ≤415 V in AC-1 is the thermal current rating for resistive loads — this contactor can carry and break that current continuously under those conditions. The 4-pole arrangement means each NO pole shares the load; for a balanced three-phase resistive heater plus neutral, you'd use three poles for the phases and one for the neutral, staying within the 55 A per-pole limit. At 56 mm wide, 64 mm tall, and 93 mm deep, this contactor fits standard DIN-rail enclosures or can be plate-mounted. The IP2X finger protection means the live terminals are shielded against accidental contact — enough for a general-purpose control cabinet but not for washdown areas. Operating ambient is -5 to 55 °C, with storage from -60 to 80 °C; the TH protective treatment (pollution degree 3 per IEC 60068) means it handles the dusty, humid conditions common in industrial panels without conformal coating.","metaTitle":"Schneider Electric LC1E32004V7IN Easy TeSys Contactor, 4P, 5","metaDescription":"Schneider Electric LC1E32004V7IN Easy TeSys Control contactor, 4P (4NO), AC-1 rated 55A at ≤415V. Obsolete — sourced to order against RFQ. DIN rail or plate mount.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"93 mm","Range":"Easy TeSys","Width":"56 mm","Height":"64 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"DIN rail Plate","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"4P","Operating altitude":"3000 m","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068","Utilisation category":"AC-1","Contactor application":"Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor closed (10 Gn for 11 ms) Shocks contactor open (6 Gn for 11 ms)","IP degree of protection":"IP2X conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1765c20596dcbfb6bfe6e9f5eb884759.pdf","sourceUrl":"https://www.se.com/sg/en/product/LC1E32004V7IN/contactoreasy-tesys-controllc1e4p4noac1415v55a400v/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E32004V7IN/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings of the LC1E32004V7IN?","answer":"It is a 4-pole (4 NO) contactor rated 55 A in AC-1 utilisation category at ≤415 V, with a 400 V coil. It mounts on DIN rail or a plate, measures 56 x 64 x 93 mm, and carries certifications to EN/IEC 60947-1, -4-1, -5-1 and GB/T equivalents."},{"question":"What compliance documentation is available for this contactor?","answer":"The contactor is certified to EN/IEC 60947-1 (general rules), EN/IEC 60947-4-1 (contactors and motor-starters), EN/IEC 60947-5-1 (control circuit devices), and the Chinese GB/T 14048.1, 14048.4, 14048.5 equivalents. It also meets IEC 60695-2-1 for glow-wire fire resistance at 850 °C and has TH protective treatment per IEC 60068 for pollution degree 3."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E32004V7IN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E32004V7IN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}