{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E3210M7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E3210M7","canonicalUrl":"https://aoctrl.com/schneider/LC1E3210M7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E3210M7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control, contactor, LC1E3210M7, 3P (3NO), AC-3/AC-3e ≤440V 32A, 220V AC coil 50/60Hz, 1NO auxiliary contact.","salesMarkdown":"The AC-3e rating extends that capability to energy-efficient motors with higher inrush profiles. For resistive loads (AC-1), the same poles handle the full thermal current without derating, making this a single-part solution for mixed motor-and-heater panels. The 220 V AC coil draws from a 50/60 Hz control supply, with a guaranteed non-overlap time of 1.5 ms between NC and NO contacts on both energisation and de-energisation — a critical parameter for interlocking circuits where momentary bridging of power and control circuits must not occur. Mounts on either DIN rail or plate, with a footprint of 56 mm wide by 84 mm high and 86 mm depth — compact enough for high-density panels. The IP2X finger-safe front cover meets IEC 60529, so it can sit in a control cabinet without additional shrouding over the terminals. Rated for operation at ambient temperatures from -5 °C to 55 °C, with storage capability from -60 °C to 80 °C and coil operation from -20 °C to 70 °C. Full rated performance up to 3000 m altitude without derating; above that, consult the thermal derating curve for air-density effects on heat dissipation. Also complies with EN/IEC 60335-1 Clause 30.2 and EN/IEC 60335-2-40 Annex JJ for glow-wire / fire resistance in household and heat-pump applications. The 850 °C glow-wire test per IEC 60695-2-1 is passed, confirming the thermoplastic materials self-extinguish under fault heat.","metaTitle":"Schneider Electric LC1E3210M7 Easy TeSys Contactor, 32A AC-3","metaDescription":"LC1E3210M7 Easy TeSys Control contactor, 3P (3NO), AC-3/AC-3e ≤440V 32A, 220V AC 50/60Hz coil, 1NO aux. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"86 mm","Range":"Easy TeSys","Width":"56 mm","Height":"84 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"DIN rail Plate","Non-overlap time":"1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"3P","Operating altitude":"3000 m without derating","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068-2-30 test Db","Utilisation category":"AC-3 AC-3e AC-1","Contactor application":"Motor control Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor closed (10 Gn for 11 ms) Shocks contactor open (6 Gn for 11 ms)","IP degree of protection":"IP2X conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$45.39","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/85cf75666f4267645e3f676295c2dcd8.pdf","sourceUrl":"https://www.se.com/sa/en/product/LC1E3210M7/contactoreasy-tesys-controllc1e3p3noac3-ac3e440v32a220v-ac-coil50-60hz1no-auxiliary-contact/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E3210M7/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for the LC1E3210M7?","answer":"Three-pole contactor rated 32 A in AC-3/AC-3e duty at ≤440 V, with a 220 V AC 50/60 Hz coil and one normally-open auxiliary contact. Covers AC-1 resistive loads at the same thermal current. Mounts on DIN rail or plate."},{"question":"What compliance standards does the LC1E3210M7 meet?","answer":"Compliant with EN/IEC 60947-1, -4-1, -5-1, GB/T 14048.1/4/5, and EN/IEC 60335-1 Clause 30.2 and 60335-2-40 Annex JJ. Fire resistance tested at 850 °C per IEC 60695-2-1."},{"question":"What is the physical size of the LC1E3210M7?","answer":"Width 56 mm, height 84 mm, depth 86 mm. Fits standard DIN-rail or plate mounting."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E3210M7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E3210M7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}