{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E38004F7IN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E38004F7IN","canonicalUrl":"https://aoctrl.com/schneider/LC1E38004F7IN","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E38004F7IN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys LC1E38004F7IN, 4-pole contactor (4 NO), AC-1 resistive load 20 A at ≤415 V, 110 V AC coil, DIN-rail or plate mount.","salesMarkdown":"The Schneider Easy TeSys LC1E38004F7IN is a 4-pole contactor with four normally-open (4 NO) main poles, rated for AC-1 utilisation category — meaning it's built for resistive loads like heaters or lighting banks, not for motor switching. The AC-1 rating at ≤415 V is 20 A, and the coil is 110 V AC. That AC-1 duty class is the one that governs the real use: resistive loads draw steady current with no inrush, so the contactor doesn't need the arc-quenching headroom of an AC-3 motor-rated part. Depth is 93 mm, height 64 mm. The IP2X finger protection means it's safe for open-panel mounting inside an enclosure. ## What the standards and ratings mean for fit The contactor complies with EN/IEC 60947-1 (general rules), 60947-4-1 (contactors and motor-starters), and 60947-5-1 (control-circuit devices). The GB/T equivalents cover the Chinese market. Altitude rating is 3000 m — above that, derate for air density and dielectric strength. Mechanical robustness is specified for vibration (1.5 Gn open, 3 Gn closed) and shock (6 Gn open, 10 Gn closed), so it holds up on a machine subject to moderate mechanical stress. At 56 mm wide and 93 mm deep, it takes up one standard 4-pole contactor slot on the DIN rail. The 110 V AC coil is a common control voltage — verify the control transformer taps match. For resistive loads, no snubber is strictly required, but if the load is switched frequently, a varistor across the coil extends contact life.","metaTitle":"Schneider Easy TeSys LC1E38004F7IN Contactor, 4P NO, AC-1 20","metaDescription":"Schneider Easy TeSys LC1E38004F7IN 4-pole contactor, 4 NO, AC-1 20 A at ≤415 V, 110 V AC coil. Active production. DIN-rail or plate mount. Order today.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"93 mm","Range":"Easy TeSys","Width":"56 mm","Height":"64 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"Plate DIN rail","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"4P","Operating altitude":"3000 m","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068","Utilisation category":"AC-1","Contactor application":"Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor closed (10 Gn for 11 ms) Shocks contactor open (6 Gn for 11 ms)","IP degree of protection":"IP2X conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/LC1E38004F7IN/easy-tesys-contactor-4p4-no-ac1-415-v-20a-110-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E38004F7IN/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative in the same family?","answer":"Within the Easy TeSys range, the closest peer would be a 4-pole contactor with the same coil voltage but a different current rating or pole configuration. The LC1E38004F7IN is the 20 A AC-1, 4 NO variant with a 110 V AC coil. If you need a different coil voltage or a 4-pole with 2 NO + 2 NC, the Easy TeSys family covers those — but the pinout and footprint are consistent across the range, so swapping within the family is straightforward."},{"question":"What are the key ratings for this contactor?","answer":"It is a 4-pole normally-open contactor rated AC-1 at 20 A for resistive loads up to 415 V. The coil is 110 V AC. Mechanical ratings include IP2X protection, operation from -5 to 55 °C, and altitude up to 3000 m."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E38004F7IN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E38004F7IN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}