{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E38008V7IN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E38008V7IN","canonicalUrl":"https://aoctrl.com/schneider/LC1E38008V7IN","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E38008V7IN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control, LC1E, 4P (2NO+2NC), AC-1, ≤415V, 60A (IN), 400V.","salesMarkdown":"The Schneider Electric LC1E38008V7IN is a 4-pole contactor from the Easy TeSys Control range, configured 2NO+2NC and rated for AC-1 resistive loads at 60 A up to 415 V. It is designed for switching resistive heating elements, lighting banks, or other non-inductive loads where inrush current is minimal — the AC-1 utilisation category (per EN/IEC 60947-4-1) defines this duty. The AC-1 rating of 60 A at 415 V is the resistive-load current the main poles can carry continuously and interrupt without arc damage. Do not apply this contactor to motor or inductive loads at that current — AC-3 or AC-4 duty would require significant derating. The 4-pole arrangement (2NO+2NC) suits applications needing both normally-open and normally-closed power paths in one device, such as dual-speed heater stages or changeover circuits. Mechanical robustness is specified for vibration (3 Gn closed, 1.5 Gn open) and shock (10 Gn closed), which covers most industrial panel environments without additional damping. IP2X protection means the contactor body is finger-safe but not sealed against dust or moisture — it belongs inside an enclosure rated to the line environment. Fire resistance tested to 850 °C per IEC 60695-2-1. Protective treatment is TH (pollution degree 3) per IEC 60068, meaning it tolerates conductive pollution typical of industrial control rooms — not clean-room or outdoor exposure without an enclosure.","metaTitle":"Schneider Electric LC1E38008V7IN Easy TeSys Contactor, 4P, 6","metaDescription":"Schneider Electric LC1E38008V7IN Easy TeSys Control contactor, 4P (2NO+2NC), AC-1 rated 60A at 415V. Obsolete — sourced to order against RFQ. DIN rail mount, EN/IEC 60947 compliant","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"93 mm","Range":"Easy TeSys","Width":"56 mm","Height":"64 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"DIN rail Plate","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"4P","Operating altitude":"3000 m","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068","Utilisation category":"AC-1","Contactor application":"Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor closed (10 Gn for 11 ms) Shocks contactor open (6 Gn for 11 ms)","IP degree of protection":"IP2X conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/59b2283d99e145d3f62d998f16ba8602.pdf","sourceUrl":"https://www.se.com/sg/en/product/LC1E38008V7IN/contactoreasy-tesys-controllc1e4p2no+2ncac1415v60ain400v/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E38008V7IN/alternatives.json"},"ai":{"faq":[{"question":"What replaces the LC1E38008V7IN?","answer":"No official successor order code is listed in the lifecycle record. A replacement must be selected by matching pole count (4P, 2NO+2NC), coil voltage, and AC-1 current rating (60 A at 415 V) from the current Easy TeSys or TeSys Deca range."},{"question":"What are the key ratings for this contactor?","answer":"AC-1 utilisation category, rated 60 A at up to 415 V for resistive loads. Four poles configured 2NO+2NC. Mounts on DIN rail or plate. Operating temperature range -5 to +55 °C."},{"question":"What compliance documentation is available?","answer":"The contactor is designed to EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and GB/T 14048 series. Fire resistance is 850 °C per IEC 60695-2-1. Protective treatment is TH (pollution degree 3) per IEC 60068."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E38008V7IN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E38008V7IN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}