{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E3801B6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E3801B6","canonicalUrl":"https://aoctrl.com/schneider/LC1E3801B6","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E3801B6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control, LC1E3801B6, 3-pole contactor, 38 A AC-3/AC-3e, 24 V AC 60 Hz coil, 1 NC auxiliary contact.","salesMarkdown":"The Schneider Electric LC1E3801B6 is a 3-pole contactor from the Easy TeSys Control range, rated 38 A in AC-3/AC-3e duty at ≤440 V — meaning it switches three-phase motor loads up to that current under full-load starting conditions. The coil is 24 V AC, 60 Hz, and the contactor carries one normally-closed auxiliary contact. It is designed for motor control and resistive load switching, with utilisation categories AC-3 (squirrel-cage motors: starting, stopping, plugging), AC-3e (enhanced electrical endurance for motor loads), and AC-1 (non-inductive or slightly inductive loads). Compliant with EN/IEC 60947-1, -4-1, -5-1 and the corresponding GB/T standards, plus EN/IEC 60335-1 Clause 30.2 and EN/IEC 60335-2-40 Annex JJ for appliance applications. Ambient temperature range is -20 to 70 °C at the coil, with storage from -60 to 80 °C and operation from -5 to 55 °C. Mechanical robustness includes vibration resistance of 1.5 Gn (5–300 Hz) with contacts open and 3 Gn with contacts closed, plus shock resistance of 10 Gn for 11 ms (contacts closed) and 6 Gn for 11 ms (contacts open).","metaTitle":"Schneider LC1E3801B6 Easy TeSys Contactor, 38A AC-3, 24VAC","metaDescription":"Schneider Electric LC1E3801B6 Easy TeSys Control contactor. 3P 38A AC-3/AC-3e, 24V AC 60Hz coil, 1NC aux. Obsolete — sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"86 mm","Range":"Easy TeSys","Width":"56 mm","Height":"84 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"Plate DIN rail","Non-overlap time":"1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"3P","Operating altitude":"3000 m without derating","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068-2-30 test Db","Utilisation category":"AC-3 AC-3e AC-1","Contactor application":"Motor control Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor closed (10 Gn for 11 ms) Shocks contactor open (6 Gn for 11 ms)","IP degree of protection":"IP2X conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d4452da4ae5efc1867ab862b7ff222d0.pdf","sourceUrl":"https://www.se.com/in/en/product/LC1E3801B6/contactoreasy-tesys-controllc1e3p3noac3-ac3e440v38a24v-ac-coil60hz1nc-auxiliary-contact/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E3801B6/alternatives.json"},"ai":{"faq":[{"question":"What is the closest pin-compatible alternative to LC1E3801B6?","answer":"No official successor order code is listed in the lifecycle record. A direct replacement would need to be evaluated against the specific application ratings (38 A AC-3, 24 V AC 60 Hz coil, 1 NC auxiliary) and panel footprint. Contact us with the application details for a cross-reference proposal."},{"question":"What compliance documentation is available for LC1E3801B6?","answer":"The contactor is certified to EN/IEC 60947-1, -4-1, -5-1 and the corresponding GB/T standards, plus EN/IEC 60335-1 Clause 30.2 and EN/IEC 60335-2-40 Annex JJ. Fire resistance is tested to 850 °C per IEC 60695-2-1. Protective treatment is TH (pollution degree 3) per IEC 60068-2-30."},{"question":"What are the key ratings for this contactor?","answer":"Three-pole contactor rated 38 A in AC-3/AC-3e duty at ≤440 V. Coil is 24 V AC, 60 Hz. Includes one normally-closed auxiliary contact. Mounts on plate or DIN rail. IP2X protection."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E3801B6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E3801B6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}