{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E3801B7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E3801B7","canonicalUrl":"https://aoctrl.com/schneider/LC1E3801B7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E3801B7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control LC1E contactor, 3P(3NO), AC-3/AC-3e ≤440V 38A, 24V AC 50/60Hz coil, 1NC auxiliary contact, DIN rail mount.","salesMarkdown":"The Schneider Electric LC1E3801B7 is a 3-pole contactor from the Easy TeSys Control range, rated 38 A in AC-3 and AC-3e utilization categories at up to 440 V. This is the part you spec when the BOM calls for a standard motor-switching contactor on a 24 V AC control circuit — no surprises, no special-order lead time. The 38 A AC-3 rating is the motor-switching current — it handles starting and running of a three-phase induction motor up to that load. AC-3e is the same duty but with an extended electrical life profile for high-cycle applications. The 24 V AC coil is common in older control systems and some export panels. The 50/60 Hz compatibility means it works on either mains frequency without a coil change. The 1.5 ms guaranteed non-overlap time between NC and NO contacts prevents a momentary short-circuit when switching between the two — important for reversing or star-delta starter circuits. The IP2X finger protection is standard for enclosed panels — no special handling for live parts. The 56 mm width means it takes three modules of space — plan your DIN rail fill factor accordingly. The 1.5 ms non-overlap time is baked into the contactor's mechanical interlock — no external timing relay needed for basic NC/NO separation. For reversing applications, pair two of these with a mechanical interlock accessory. Compliant with EN/IEC 60947-1, 60947-4-1, and 60947-5-1 — the core contactor and control circuit standards. Also meets GB/T 14048.1/4/5 for Chinese market installations, and EN/IEC 60335-1 Clause 30.2 and 60335-2-40 Annex JJ for appliance and HVAC applications.","metaTitle":"Schneider LC1E3801B7 Easy TeSys Contactor, 38A, 24V AC Coil","metaDescription":"Active LC1E3801B7 contactor from Schneider Electric's Easy TeSys Control range. 38A AC-3/AC-3e, 3P(3NO), 24V AC 50/60Hz coil, 1NC aux. DIN rail mount. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"86 mm","Range":"Easy TeSys","Width":"56 mm","title":"LC1E3801B7","Height":"84 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ","description":"Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3/AC-3e,<=440V,38A,24V AC coil,50/60Hz,1NC auxiliary contact","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"Plate DIN rail","Non-overlap time":"1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"3P","Operating altitude":"3000 m without derating","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068-2-30 test Db","Utilisation category":"AC-3 AC-3e AC-1","Contactor application":"Motor control Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor closed (10 Gn for 11 ms) Shocks contactor open (6 Gn for 11 ms)","IP degree of protection":"IP2X conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/576778108fbdc55458f47cd3a93657d9.pdf","sourceUrl":"https://www.se.com/hk/en/product/LC1E3801B7/contactoreasy-tesys-controllc1e3p3noac3-ac3e440v38a24v-ac-coil50-60hz1nc-auxiliary-contact/"},"ai":{"faq":[{"question":"What are the key ratings for the LC1E3801B7?","answer":"The LC1E3801B7 is a 3-pole contactor rated 38 A in AC-3 and AC-3e utilization categories at up to 440 V. It has a 24 V AC 50/60 Hz coil and one NC auxiliary contact. It mounts on a DIN rail or plate."},{"question":"What standards does the LC1E3801B7 comply with?","answer":"It complies with EN/IEC 60947-1, 60947-4-1, 60947-5-1, GB/T 14048.1/4/5, and EN/IEC 60335-1 Clause 30.2 and 60335-2-40 Annex JJ. It also has 850 °C fire resistance per IEC 60695-2-1 and TH protective treatment per IEC 60068-2-30."},{"question":"What is the depth of the LC1E3801B7?","answer":"The depth is 86 mm. Width is 56 mm and height is 84 mm."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E3801B7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E3801B7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}