{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E3801M5WB","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E3801M5WB","canonicalUrl":"https://aoctrl.com/schneider/LC1E3801M5WB","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E3801M5WB","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control, LC1E3801M5WB, 3P contactor, AC-3/AC-3e 38A ≤440V, 220V AC 50Hz coil, 1NC auxiliary contact.","salesMarkdown":"The LC1E3801M5WB is a Schneider Electric Easy TeSys Control contactor, now classified as obsolete. It is a 3-pole (3NO) device rated for AC-3 and AC-3e utilisation categories at 38 A up to 440 V, with a 220 V AC 50 Hz wide-range coil and one normally-closed auxiliary contact. This is a motor-control and resistive-load switching contactor built to EN/IEC 60947-4-1 and GB/T 14048.4 standards, with IP20 finger-safe protection for panel installation. The AC-3e rating extends this with enhanced electrical endurance for high-cycle applications like conveyors or compressors. The 220 V AC 50 Hz coil is a wide-range type, meaning it holds in across a voltage band around the nominal, but the coil dropout threshold still follows the standard IEC 60947-4-1 undervoltage release curve. The single NC auxiliary contact (1NC) is wired as a feedback or interlock signal; if your circuit requires more auxiliary poles or a different configuration, an external auxiliary contact block must be added. The LC1E3801M5WB carries declarations of conformity to EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and the equivalent GB/T 14048 series for the Chinese market. It also meets EN/IEC 60335-1 Clause 30.2 for glow-wire / fire resistance and EN/IEC 60335-2-40 Annex JJ for heat pump / air-conditioning applications. It is rated for operation up to 3000 m altitude without derating. ## Mechanical & Environmental Limits The contactor is rated for vibration resistance at 1.5 Gn (open) and 3 Gn (closed) across 5–300 Hz, and shock resistance at 6 Gn (open) and 10 Gn (closed) for 11 ms. These ratings confirm suitability for standard industrial panel environments with moderate mechanical stress.","metaTitle":"Schneider LC1E3801M5WB Easy TeSys Contactor, 38A AC-3, 220V","metaDescription":"Obsolete Schneider LC1E3801M5WB Easy TeSys Control contactor. 3P, 38A AC-3/AC-3e ≤440V, 220V AC 50Hz coil, 1NC aux. Sourced to order against RFQ. EN/IEC/GB certified.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"86 mm","Range":"Easy TeSys","Width":"56 mm","Height":"84 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"Plate DIN rail","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"3P","Operating altitude":"3000 m without derating","Protective treatment":"TH conforming to IEC 60068","Utilisation category":"AC-3 AC-3e AC-1","Contactor application":"Motor control Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor closed (10 Gn for 11 ms) Shocks contactor open (6 Gn for 11 ms)","IP degree of protection":"IP20 conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for signalling circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/eg/en/product/LC1E3801M5WB/contactoreasy-tesys-controllc1e3p3noac3-ac3e440v38a220v-ac-coil50hz-wide-range1nc-auxiliary-contact/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E3801M5WB/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation does Schneider provide for this contactor?","answer":"The LC1E3801M5WB is certified to EN/IEC 60947-1, 60947-4-1, 60947-5-1, and the Chinese GB/T 14048 equivalents. It also meets EN/IEC 60335-1 Clause 30.2 and EN/IEC 60335-2-40 Annex JJ for appliance and heat-pump applications. Fire resistance is 850 °C per IEC 60695-2-1, and it carries TH protective treatment for tropical environments."},{"question":"What are the key ratings for the LC1E3801M5WB?","answer":"It is a 3-pole contactor rated 38 A in AC-3/AC-3e duty at ≤440 V, with a 220 V AC 50 Hz coil and one normally-closed auxiliary contact. It is designed for motor control and resistive loads."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E3801M5WB","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E3801M5WB when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}