{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E3801Q6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E3801Q6","canonicalUrl":"https://aoctrl.com/schneider/LC1E3801Q6","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E3801Q6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control LC1E, contactor, 3P(3NO), AC-3/AC-3e ≤440V, 38A, 380V AC coil 60Hz, 1NC auxiliary contact.","salesMarkdown":"It switches 38 A in AC-3 duty at up to 440 V, with a 380 V AC coil at 60 Hz and a single NC auxiliary contact built in. Rated utilisation categories AC-3, AC-3e, and AC-1 mean it handles motor start/stop, high-inrush motor loads, and resistive heating elements without derating down to the listed voltage. IP2X finger-safe protection on the front, so it can sit in a standard enclosure without additional shrouding on the operator side. ## Lifecycle reality If a replacement is required for a design-in, the Easy TeSys range has been superseded by newer contactor families — verify coil voltage and auxiliary configuration against a current equivalent before committing the BOM line. Mechanical robustness specs — 3 Gn vibration closed, 10 Gn shock closed — mean it stays latched through pump starts and conveyor impacts. The 850 °C fire resistance (IEC 60695-2-1) is the glow-wire test, relevant for appliance and HVAC applications covered by EN/IEC 60335. The wider storage window matters for spares kept in unheated warehouses.","metaTitle":"Schneider LC1E3801Q6 Easy TeSys Contactor, 38A AC-3, 380V 60","metaDescription":"Obsolete Schneider LC1E3801Q6 Easy TeSys Control contactor, 3P, 38A AC-3/AC-3e ≤440V, 380V AC 60Hz coil, 1NC aux. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"86 mm","Range":"Easy TeSys","Width":"56 mm","Height":"84 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"Plate DIN rail","Non-overlap time":"1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"3P","Operating altitude":"3000 m without derating","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068-2-30 test Db","Utilisation category":"AC-3 AC-3e AC-1","Contactor application":"Motor control Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor closed (10 Gn for 11 ms) Shocks contactor open (6 Gn for 11 ms)","IP degree of protection":"IP2X conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/875965520e9d52a506b3d55ca8e85e6c.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC1E3801Q6/contactoreasy-tesys-controllc1e3p3noac3-ac3e440v38a380v-ac-coil60hz1nc-auxiliary-contact/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E3801Q6/alternatives.json"},"ai":{"faq":[{"question":"What compliance standards does the LC1E3801Q6 meet?","answer":"It complies with EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, GB/T 14048.1/4/5, and EN/IEC 60335-1 Clause 30.2 and 60335-2-40 Annex JJ for appliance use. Fire resistance is 850 °C per IEC 60695-2-1."},{"question":"What is the physical size of this contactor?","answer":"Width 56 mm, height 84 mm, depth 86 mm. It mounts on a DIN rail or plate."},{"question":"What coil voltage and frequency does it need?","answer":"380 V AC at 60 Hz. The coil draws power from that supply."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E3801Q6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E3801Q6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}