{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E3810M6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E3810M6","canonicalUrl":"https://aoctrl.com/schneider/LC1E3810M6","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E3810M6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control, LC1E3810M6, 3-pole contactor, 38 A AC-3/AC-3e, 220 V AC 60 Hz coil, 1 NO auxiliary contact, DIN rail mount.","salesMarkdown":"The Schneider Electric LC1E3810M6 is a 3-pole contactor from the Easy TeSys Control range, rated for 38 A in AC-3 and AC-3e duty categories up to 440 V. That means it's sized to switch three-phase motor loads — compressors, pumps, conveyors — right up to that current. The 220 V AC 60 Hz coil pulls in reliably, and the built-in 1 NO auxiliary contact gives you a feedback or interlock signal without adding a separate block. The 56 mm width and 84 mm height mean it fits a standard 4-module footprint on the rail — no surprises when you're laying out a panel. Depth at 86 mm leaves room for wiring gutters without jamming the gland plate. Operating altitude goes to 3000 m without derating, so it's fine for high-altitude installations like mine sites or mountain-top equipment. It also carries the EN/IEC 60335-1 Clause 30.2 glow-wire test and EN/IEC 60335-2-40 Annex JJ for heat pump applications, so it's cleared for appliance and HVAC panels. A 38 A contactor on 400 V three-phase can typically handle a 15–18.5 kW motor, depending on the motor's full-load current and duty cycle. The AC-3e rating adds an 'enhanced' category for higher electrical endurance on certain motor starts — it's a bonus, not a restriction. If you're switching resistive loads (heaters, ovens), the AC-1 rating is higher, but the AC-3 number is the one that governs for inductive motor loads. Vibration tolerance is 1.5 Gn open and 3 Gn closed, with shock at 10 Gn for 11 ms. That's enough for most industrial machinery — conveyors, compressors, machine tools. For the control panel, keep ambient below 55 °C for continuous operation.","metaTitle":"Schneider LC1E3810M6 Easy TeSys Contactor, 38A AC-3, 220V AC","metaDescription":"Schneider Electric LC1E3810M6 Easy TeSys Control contactor, 3P, 38A in AC-3/AC-3e, 220V AC 60Hz coil, 1NO aux. Active production. IEC/GB/T standards. DIN rail mount.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"86 mm","Range":"Easy TeSys","Width":"56 mm","Height":"84 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"Plate DIN rail","Non-overlap time":"1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"3P","Operating altitude":"3000 m without derating","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068-2-30 test Db","Utilisation category":"AC-3 AC-3e AC-1","Contactor application":"Motor control Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor closed (10 Gn for 11 ms) Shocks contactor open (6 Gn for 11 ms)","IP degree of protection":"IP2X conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/089bedd41a73bd4cd65422382d0129b9.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC1E3810M6/contactoreasy-tesys-controllc1e3p3noac3-ac3e440v38a220v-ac-coil60hz1no-auxiliary-contact/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E3810M6/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this contactor?","answer":"38 A in AC-3/AC-3e duty up to 440 V, with a 220 V AC 60 Hz coil. It has 3 poles (3 NO main contacts) and 1 NO auxiliary contact. The non-overlap time between NC and NO contacts is guaranteed at 1.5 ms."},{"question":"What standards does the LC1E3810M6 comply with?","answer":"It complies with EN/IEC 60947-1, -4-1, -5-1, and the corresponding GB/T standards. It also meets EN/IEC 60335-1 Clause 30.2 and EN/IEC 60335-2-40 Annex JJ for appliance and heat pump applications. Fire resistance is 850 °C per IEC 60695-2-1."},{"question":"How does the LC1E3810M6 mount in a panel?","answer":"It mounts on a DIN rail or directly to a plate. Dimensions are 56 mm wide, 84 mm high, and 86 mm deep. Operating altitude goes to 3000 m without derating."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E3810M6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E3810M6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}