{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E3810Q7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E3810Q7","canonicalUrl":"https://aoctrl.com/schneider/LC1E3810Q7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E3810Q7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control LC1E3810Q7, 3P contactor, AC-3/AC-3e 38 A ≤440 V, 380 V AC coil 50/60 Hz, 1NO auxiliary contact, obsolete.","salesMarkdown":"The LC1E3810Q7 is a 3-pole contactor from the Easy TeSys Control range, rated 38 A in AC-3 duty at ≤440 V — that is the motor-switching current, not the resistive load rating. It carries a 380 V AC coil (50/60 Hz) and one normally-open auxiliary contact. The part is now listed as obsolete by the manufacturer, so any procurement decision should account for last-time-buy or replacement planning. AC-3 rating of 38 A at ≤440 V covers motor switching for three-phase induction motors. The AC-3e category extends the same rating for energy-efficient motors with higher inrush. Mechanical robustness: the contactor withstands 1.5 Gn vibration when open, 3 Gn when closed, and 10 Gn shock for 11 ms when closed. That is typical for general industrial panel mounting — not rated for high-shock mobile equipment, but fine for fixed conveyors, pumps, and compressors. Operation limited to -5 to 55 °C — that is the functional window for coil pick-up and hold. Designed to EN/IEC 60947-1, -4-1 (contactor), and -5-1 (control circuit), plus Chinese GB/T equivalents. Protective treatment TH conforms to IEC 60068-2-30 for damp heat (pollution degree 3). IP2X finger protection on the front face. ## Sourcing Reality for an Obsolete Part The LC1E3810Q7 is obsolete per the manufacturer. No successor order code is listed.","metaTitle":"LC1E3810Q7 Easy TeSys Contactor, 38A, 380V AC Coil, Obsolete","metaDescription":"Obsolete LC1E3810Q7 Easy TeSys 3P contactor, 38A AC-3 at ≤440V, 380V AC coil, 1NO aux. Sourced to order against RFQ. Standards EN/IEC 60947.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"86 mm","Range":"Easy TeSys","Width":"56 mm","Height":"84 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"Plate DIN rail","Non-overlap time":"1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"3P","Operating altitude":"3000 m without derating","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068-2-30 test Db","Utilisation category":"AC-3 AC-3e AC-1","Contactor application":"Motor control Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor closed (10 Gn for 11 ms) Shocks contactor open (6 Gn for 11 ms)","IP degree of protection":"IP2X conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c5d3aa3ee6aafa0d6c03a42936004b76.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC1E3810Q7/contactoreasy-tesys-controllc1e3p3noac3-ac3e440v38a380v-ac-coil50-60hz1no-auxiliary-contact/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E3810Q7/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings of the LC1E3810Q7?","answer":"Three-pole contactor, 38 A in AC-3/AC-3e at ≤440 V, 380 V AC coil 50/60 Hz, one NO auxiliary contact. Mounts on plate or DIN rail, 56 mm wide."},{"question":"What is the non-overlap time and why does it matter?","answer":"Guaranteed 1.5 ms on both energisation and de-energisation between NC and NO contacts. This prevents simultaneous closure in reversing or safety circuits, avoiding phase-to-phase shorts."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E3810Q7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E3810Q7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}