{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E3810U5","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E3810U5","canonicalUrl":"https://aoctrl.com/schneider/LC1E3810U5","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E3810U5","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact TVS, LC1E3810U5, 3-pole contactor, 38 A AC-3 at ≤440 V, 240 V AC coil, DIN-rail mount.","salesMarkdown":"The LC1E3810U5 is a 3-pole EasyPact TVS contactor from the Easy TeSys Control range, rated 38 A in AC-3 duty at ≤440 V with a 240 V AC coil. That AC-3 rating means it's sized for squirrel-cage motor switching — the 38 A figure governs the full-voltage starting and stopping of motors up to that current. It also carries AC-3e and AC-1 utilisation categories, so it handles the higher electrical endurance of AC-3e for IEC 60947-4-1 applications and resistive loads up to its AC-1 rating. The 56 mm width and 84 mm height fit standard panel spacing — no oddball footprint that forces a layout change. That 1.5 ms window prevents a momentary short-circuit across the power circuit during pole transition — if your control scheme relies on mechanical interlocking, this part has the built-in timing to back it up. Permissible ambient temperature spans -20 to 70 °C at the coil, with storage down to -60 °C and operation at -5 to 55 °C. Fire resistance rated at 850 °C conforming to IEC 60695-2-1, and the part complies with EN/IEC 60947-1, -4-1, -5-1 plus GB/T equivalents and EN/IEC 60335-1 Clause 30.2 and -2-40 Annex JJ. That last pair matters if the contactor ends up in an appliance or HVAC circuit — the glow-wire test at 850 °C is a hard requirement for those standards.","metaTitle":"Schneider LC1E3810U5 EasyPact TVS Contactor, 38A AC-3, 240V","metaDescription":"Active-production 3-pole contactor rated 38A AC-3 at ≤440V, 240V AC coil. DIN-rail mount, EN/IEC 60947 certified. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"86 mm","Range":"Easy TeSys","Width":"56 mm","Height":"84 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"Plate DIN rail","Non-overlap time":"1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"3P","Operating altitude":"3000 m without derating","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068-2-30 test Db","Utilisation category":"AC-3 AC-3e AC-1","Contactor application":"Motor control Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor closed (10 Gn for 11 ms) Shocks contactor open (6 Gn for 11 ms)","IP degree of protection":"IP2X conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$46.44","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/fe3a3c8cbde65d6ff2be3a1cc803c15b.pdf","sourceUrl":"https://www.se.com/ae/en/product/LC1E3810U5/easypact-tvs-contactor-3p3-no-ac3-440-v-38a-240-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E3810U5/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this contactor?","answer":"Rated 38 A in AC-3 duty at ≤440 V with a 240 V AC coil. It is a 3-pole contactor (3 NO) with AC-3, AC-3e, and AC-1 utilisation categories. The non-overlap time between NC and NO contacts is 1.5 ms guaranteed on both energisation and de-energisation."},{"question":"What standards does the LC1E3810U5 comply with?","answer":"It complies with EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, GB/T 14048.1, GB/T 14048.4, GB/T 14048.5, and EN/IEC 60335-1 Clause 30.2 and EN/IEC 60335-2-40 Annex JJ. Fire resistance is rated at 850 °C per IEC 60695-2-1."},{"question":"What is the mounting and dimensions of this contactor?","answer":"It mounts on a DIN rail or plate. Dimensions are 86 mm depth, 56 mm width, and 84 mm height. IP degree of protection is IP2X."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E3810U5","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E3810U5 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}