{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E40004M5WB","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E40004M5WB","canonicalUrl":"https://aoctrl.com/schneider/LC1E40004M5WB","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E40004M5WB","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys LC1E40004M5WB, 4-pole contactor, 60 A AC-1, 220 V AC 50 Hz coil, screw clamp terminals, DIN rail/plate mount.","salesMarkdown":"The coil is 220 V AC 50 Hz, wide-range control circuit type, with a drop-out threshold of 0.3 to 0.6 Uc and operational range of 0.7 to 1.25 Uc across -5 to 55 °C. Breaking capacity is 320 A at 440 V AC. Mounts on DIN rail or plate. Dimensions are 85 mm wide, 127 mm high, 110 mm deep — a compact footprint for a 60 A 4-pole block. Power circuit terminals accept 2.5 to 25 mm² solid or flexible with cable end; control circuit terminals take 1 to 4 mm². Tightening torque is 5 N.m on the power side, 1.2 N.m on control. The IP2X finger protection means it is safe for open-panel mounting but not for washdown environments. Heat dissipation runs 6 to 10 W for the control circuit and 5.4 W per pole under AC-1 load. In a crowded DIN-rail enclosure, that thermal load needs to be factored into the cabinet cooling budget — especially if the contactor cycles near its maximum operating rate of 1200 cycles per hour at 60 °C. Protective treatment is TH conforming to IEC 60068-2-30 (damp heat, cyclic). These certifications cover the contactor for industrial control panels in most global markets.","metaTitle":"Schneider Electric LC1E40004M5WB Easy TeSys Contactor, 60 A","metaDescription":"Schneider Electric LC1E40004M5WB Easy TeSys contactor, 60 A rated operational current at 440 V AC-1, 4 NO poles, 220 V AC 50 Hz coil. Current lifecycle stage. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"110 mm","Range":"Easy TeSys","Width":"85 mm","Height":"127 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5","Operating time":"20...26 ms on closing 8...12 ms on opening","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Heat dissipation":"6...10 W for control circuit","Mounting support":"DIN rail Plate","Pollution degree":"3","Range of product":"Easy TeSys Control","Average impedance":"1.5 mOhm - Ith 60 A 50 Hz for power circuit","Device short name":"LC1E","Poles description":"4P","Tightening torque":"Control circuit: 1.2 N.m Power circuit: 5 N.m","Inrush power in VA":"160 VA 50 Hz cos phi 0.75 (at 20 °C)","Operating altitude":"3000 m without derating","Control circuit type":"AC at 50 Hz wide range","Overvoltage category":"III","Protective treatment":"TH conforming to IEC 60068-2-30 test Db","Utilisation category":"AC-1","Contactor application":"Resistive load","Electrical durability":"350000 cycles AC-1","Mechanical durability":"5000000 cycles","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms)","Associated fuse rating":"80 A gG at <= 690 V coordination type 1 for power circuit","Maximum operating rate":"1200 cyc/h 60 °C","Connections - terminals":"Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1...2.5 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 2.5...25 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 2.5...10 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: solid Control circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: solid Power circuit: screw clamp terminals 1 2.5...25 mm² - cable stiffness: solid Power circuit: screw clamp terminals 2 2.5...16 mm² - cable stiffness: solid","IP degree of protection":"IP2X conforming to IEC 60529","Rated breaking capacity":"320 A at 440 V for power circuit conforming to IEC 60947","Pole contact composition":"4 NO","Product or component type":"Contactor","Irms rated making capacity":"400 A at 440 V AC for power circuit conforming to IEC 60947-4-1","Power dissipation per pole":"5.4 W AC-1","[Uc] control circuit voltage":"220 V AC 50 Hz","Auxiliary contact composition":"Without","[Ui] rated insulation voltage":"690 V conforming to IEC 60947-4-1","Control circuit voltage limits":"0.3...0.6 Uc (-5...55 °C):drop-out 50 Hz 0.7...1.25 Uc (-5...55 °C):operational 50 Hz","[Ie] rated operational current":"60 A (at <55 °C) at <= 440 V AC AC-1 for power circuit","[Ue] rated operational voltage":"Power circuit: <= 690 V AC 50/60 Hz","Hold-in power consumption in VA":"15 VA 50 Hz cos phi 0.3 (at 20 °C)","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947","[Icw] rated short-time withstand current":"320 A 40 °C - 10 s for power circuit 165 A 40 °C - 60 s for power circuit 72 A 40 °C - 600 s for power circuit","[Ith] conventional free air thermal current":"60 A (at 55 °C) for power circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/471a3b651735c76172dffa538b278e74.pdf","sourceUrl":"https://www.se.com/sg/en/product/LC1E40004M5WB/easypact-tvs-contactor-4p-ctr-60a-ac14no220v-50hz-wb/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E40004M5WB/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this contactor?","answer":"Rated operational current is 60 A at up to 440 V AC under AC-1 (resistive load). Coil voltage is 220 V AC 50 Hz. It has 4 normally-open poles. Rated insulation voltage is 690 V. Making capacity is 400 A at 440 V AC; breaking capacity is 320 A at 440 V AC."},{"question":"What mounting options does it support?","answer":"It mounts on DIN rail or a plate. Dimensions are 85 mm wide, 127 mm high, 110 mm deep. Power circuit terminals accept 2.5 to 25 mm² conductors; control circuit terminals accept 1 to 4 mm²."},{"question":"What compliance documentation is available?","answer":"The contactor is certified to EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and the Chinese GB/T 14048 series. It carries a TH protective treatment rating per IEC 60068-2-30 and a fire resistance rating of 850 °C per IEC 60695-2-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E40004M5WB","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E40004M5WB when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}