{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E40004N7IN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E40004N7IN","canonicalUrl":"https://aoctrl.com/schneider/LC1E40004N7IN","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E40004N7IN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control LC1E40004N7IN, 4P contactor, AC-1 ≤415 V, 72 A, IP2X, DIN-rail mount.","salesMarkdown":"The Schneider Electric LC1E40004N7IN is a 4-pole contactor from the Easy TeSys Control range, rated 72 A in AC-1 utilisation category at ≤415 V. AC-1 covers resistive loads — heaters, lighting banks, non-inductive elements — not motor starting. The four normally-open poles switch the line side; there are no built-in auxiliary contacts on this base unit. It complies with EN/IEC 60947-1, 60947-4-1, and 60947-5-1, plus the Chinese GB/T equivalents — so it carries the certifications for a panel destined for European or Asian markets. The 72 A AC-1 rating is the continuous resistive current the contactor can carry without exceeding its thermal limit. For a panel feeding a 60 A three-phase heater bank, this contactor has headroom. But do not apply it to a motor load — AC-3 or AC-4 duty would require derating, and the contactor is not specified for those categories. It belongs inside a panel, not on a washdown line or outdoors. ## Sourcing posture If your BOM line is locked to LC1E40004N7IN and you need to keep a production line running, the smart move is to secure enough units now to cover your remaining service life — or to begin the requalification process for a current-production replacement. We can quote against an RFQ with the available quantity and condition grade.","metaTitle":"Schneider LC1E40004N7IN Easy TeSys Contactor, 4P, AC-1 72A,","metaDescription":"Schneider Easy TeSys LC1E40004N7IN 4-pole contactor, 72 A AC-1 at ≤415 V. Obsolete — sourced to order against RFQ. EN/IEC 60947, IP2X, DIN rail.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"110 mm","Range":"Easy TeSys","Width":"85 mm","Height":"127 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"Plate DIN rail","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"4P","Operating altitude":"3000 m","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068","Utilisation category":"AC-1","Contactor application":"Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms)","IP degree of protection":"IP2X conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/22750bd38d5793d387dc9cc94e8ca59f.pdf","sourceUrl":"https://www.se.com/sg/en/product/LC1E40004N7IN/contactoreasy-tesys-controllc1e4p4noac1415v72a415v/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E40004N7IN/alternatives.json"},"ai":{"faq":[{"question":"What replaces the LC1E40004N7IN?","answer":"No official successor order code is listed. A parametric replacement would need to match the 72 A AC-1 rating, 4-pole configuration, and DIN-rail mounting. Current Easy TeSys or TeSys Deca catalog numbers are the starting point, but pinout and mounting centres must be verified against the panel layout."},{"question":"What are the key ratings of this contactor?","answer":"72 A in AC-1 utilisation category at ≤415 V, 4 normally-open poles, IP2X protection, DIN-rail or plate mount, operating ambient -20 to 70 °C."},{"question":"What certifications does it carry?","answer":"It complies with EN/IEC 60947-1, 60947-4-1, 60947-5-1, and the Chinese GB/T 14048.1, 14048.4, and 14048.5 standards. Fire resistance is 850 °C per IEC 60695-2-1. Protective treatment is TH (pollution degree 3) per IEC 60068."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E40004N7IN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E40004N7IN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}