{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E40008E7IN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E40008E7IN","canonicalUrl":"https://aoctrl.com/schneider/LC1E40008E7IN","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E40008E7IN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control contactor, LC1E40008E7IN, 4P (2NO+2NC), AC-1 ≤415V 72A, 48V coil, obsolete.","salesMarkdown":"The Schneider Electric LC1E40008E7IN is an Easy TeSys Control contactor — a 4-pole (2NO+2NC) device rated for 72 A in AC-1 utilisation category at ≤415 V, with a 48 V coil. It's built to handle resistive loads in control panels, switching heater banks, lighting, or other non-inductive circuits where inrush is minimal. Operating altitude goes to 3000 m, and the ambient range is -20 to 70 °C at the coil, with storage from -60 to 80 °C. The part carries EN/IEC 60947-1, -4-1, and -5-1 plus the corresponding GB/T standards, along with 850 °C glow-wire fire resistance per IEC 60695-2-1. ## Sourcing reality — obsolete This part is now obsolete. No direct official successor is listed on the lifecycle record. For a line-down situation or BOM fill, your route is the surplus and broker channel — we source these against an RFQ. If you're designing a new panel or replacing this on a maintenance schedule, look at the current Easy TeSys range for a functionally equivalent 4-pole AC-1 contactor at the same current and voltage class. The 72 A AC-1 rating is the key number: it's the continuous current the main poles can carry in resistive duty. That's the figure that governs the BOM line — not a motor (AC-3) rating, because this contactor is not specified for inductive motor loads. The 4-pole configuration with two normally-open and two normally-closed auxiliary contacts gives flexibility for interlocking or signalling without an add-on block.","metaTitle":"Schneider LC1E40008E7IN Easy TeSys Contactor, 4P, 72A, AC-1,","metaDescription":"Schneider Electric LC1E40008E7IN Easy TeSys Control contactor, 4P (2NO+2NC), 72A AC-1 at ≤415V, 48V coil. Now obsolete — sourced to order against RFQ. Standards EN/IEC 60947.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"110 mm","Range":"Easy TeSys","Width":"85 mm","Height":"127 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"Plate DIN rail","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"4P","Operating altitude":"3000 m","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068","Utilisation category":"AC-1","Contactor application":"Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms)","IP degree of protection":"IP2X conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4a49aade27b02a850e552b9cd012c88f.pdf","sourceUrl":"https://www.se.com/sg/en/product/LC1E40008E7IN/contactoreasy-tesys-controllc1e4p2no+2ncac1415v72a48v/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E40008E7IN/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this contactor?","answer":"It's a 4-pole (2NO+2NC) contactor rated 72 A in AC-1 utilisation category at ≤415 V with a 48 V coil. It's designed for resistive loads only — not motor duty. It meets EN/IEC 60947-1, -4-1, and -5-1."},{"question":"What compliance standards does it meet?","answer":"It complies with EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and the corresponding Chinese GB/T 14048.1, GB/T 14048.4, GB/T 14048.5 standards. It also meets 850 °C glow-wire fire resistance per IEC 60695-2-1."},{"question":"How do I source this obsolete part?","answer":"Submit an RFQ. Since it's obsolete, availability is through surplus and independent channels — we quote against your order."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E40008E7IN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E40008E7IN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}