{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E40008N5WBIN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E40008N5WBIN","canonicalUrl":"https://aoctrl.com/schneider/LC1E40008N5WBIN","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E40008N5WBIN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control, contactor LC1E40008N5WBIN, 4-pole, 75 A AC-1, 415 V AC 50 Hz coil, DIN rail/plate mount.","salesMarkdown":"That is the number that governs the BOM line — do not confuse it with AC-3 motor ratings. The 4-pole configuration gives you 2 normally-open and 2 normally-closed main poles, so you can switch multiple load circuits or use one pole for a neutral. The contactor measures 85 mm wide by 127 mm tall by 110 mm deep, fitting a standard DIN-rail footprint or a plate-mount pattern. Power-circuit tightening torque is 5 N.m; control-circuit torque is 1.2 N.m. Pollution degree 3 rating confirms it handles conductive pollution typical of industrial control cabinets. It carries TH protective treatment per IEC 60068 for tropical environments. These standards cover the contactor's performance for switching, isolation, and environmental endurance in industrial control panels.","metaTitle":"Schneider LC1E40008N5WBIN Easy TeSys Contactor, 75 A AC-1, 4","metaDescription":"Schneider Electric LC1E40008N5WBIN Easy TeSys contactor. 75 A rated operational current AC-1, 415 V AC 50 Hz coil. 4-pole, 2 NO + 2 NC. DIN rail/plate mount. Current lifecycle stat","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"110 mm","Range":"Easy TeSys","Width":"85 mm","Height":"127 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5","Operating time":"20...26 ms on closing 8...12 ms on opening","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Heat dissipation":"6...10 W for control circuit","Mounting support":"DIN rail Plate","Pollution degree":"3","Range of product":"Easy TeSys Control","Average impedance":"1.5 mOhm - Ith 75 A 50 Hz for power circuit","Device short name":"LC1E","Poles description":"4P","Tightening torque":"Control circuit: 1.2 N.m Power circuit: 5 N.m","Inrush power in VA":"160 VA 50 Hz cos phi 0.75 (at 20 °C)","Operating altitude":"3000 m","Control circuit type":"AC at 50 Hz wide range","Overvoltage category":"III","Protective treatment":"TH conforming to IEC 60068","Utilisation category":"AC-1","Contactor application":"Resistive load","Electrical durability":"350000 cycles AC-1","Mechanical durability":"5000000 cycles","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms)","Associated fuse rating":"80 A gG at <= 690 V coordination type 1 for power circuit","Maximum operating rate":"1200 cyc/h 60 °C","Connections - terminals":"Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1...2.5 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 2.5...25 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 2.5...10 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: solid Control circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: solid Power circuit: screw clamp terminals 1 2.5...25 mm² - cable stiffness: solid Power circuit: screw clamp terminals 2 2.5...16 mm² - cable stiffness: solid","IP degree of protection":"IP20 conforming to IEC 60529","Rated breaking capacity":"320 A at 440 V for power circuit conforming to IEC 60947","Pole contact composition":"2 NO + 2 NC","Product or component type":"Contactor","Irms rated making capacity":"400 A at 440 V AC for power circuit conforming to IEC 60947-4-1","Power dissipation per pole":"5.4 W AC-1","[Uc] control circuit voltage":"415 V AC 50 Hz","Auxiliary contact composition":"Without","[Ui] rated insulation voltage":"690 V conforming to IEC 60947-4-1","Control circuit voltage limits":"0.3...0.6 Uc (-5...55 °C):drop-out 50 Hz 0.7...1.25 Uc (-5...55 °C):operational 50 Hz","[Ie] rated operational current":"75 A (at <40 °C) at <= 415 V AC AC-1 for power circuit","[Ue] rated operational voltage":"Power circuit: <= 690 V AC 50/60 Hz","Hold-in power consumption in VA":"15 VA 50 Hz cos phi 0.3 (at 20 °C)","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947","[Icw] rated short-time withstand current":"320 A 40 °C - 10 s for power circuit 165 A 40 °C - 60 s for power circuit 72 A 40 °C - 600 s for power circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/LC1E40008N5WBIN/easy-tesys-contactor-4p-ctr-25a-ac12no+2nc415v-50hz-wb/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E40008N5WBIN/alternatives.json"},"ai":{"faq":[{"question":"What are the key dimensions for panel layout?","answer":"Width is 85 mm, height is 127 mm, and depth is 110 mm. It mounts on a DIN rail or directly to a plate."},{"question":"What is the rated operational current and coil voltage?","answer":"The rated operational current is 75 A under AC-1 utilisation category at up to 415 V AC. The control coil is rated for 415 V AC at 50 Hz."},{"question":"What compliance documentation is available for this contactor?","answer":"The contactor is certified to EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and GB/T 14048 series standards. It also carries TH protective treatment per IEC 60068 and fire resistance to 850 °C per IEC 60695-2-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E40008N5WBIN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E40008N5WBIN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}