{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E40B10N5","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E40B10N5","canonicalUrl":"https://aoctrl.com/schneider/LC1E40B10N5","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E40B10N5","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control, LC1E40B10N5, 3P contactor, AC-3 40A ≤440 V, 415 V AC coil, obsolete.","salesMarkdown":"The coil is wound for 415 V AC, common on European 400 V three-phase networks. If you need a form-fit-function replacement within the Easy TeSys family, the closest active sibling shares the same frame size and mounting footprint but differs in coil voltage or certification revision — check the spec line yourself against your panel's coil supply and ambient temperature range. The 56 mm width and 84 mm height fit a standard contactor slot in a motor control centre; depth is 86 mm, which clears most 100 mm deep enclosures. Rated for operation at up to 3000 m altitude without derating, and ambient air temperature from -20 to 70 °C at the coil rated voltage, with storage down to -60 °C. The IP2X degree of protection means it is finger-safe but not sealed; install inside a panel with a higher enclosure rating for washdown or outdoor duty.","metaTitle":"Schneider Electric LC1E40B10N5 Easy TeSys Contactor, 40A AC-","metaDescription":"Obsolete Schneider LC1E40B10N5 Easy TeSys contactor, 3P, 40A AC-3 at 440V, 415V AC coil. Sourced to order against RFQ. Standards: EN/IEC 60947. Depth 86 mm.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"86 mm","Range":"Easy TeSys","Width":"56 mm","Height":"84 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"Plate DIN rail","Non-overlap time":"1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"3P","Operating altitude":"3000 m without derating","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068","Utilisation category":"AC-3 AC-3e AC-1","Contactor application":"Motor control Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor closed (10 Gn for 11 ms) Shocks contactor open (6 Gn for 11 ms)","IP degree of protection":"IP2X conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/LC1E40B10N5/easy-tesys-contactor-3p3-no-ac3-440-v-40a-415-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E40B10N5/alternatives.json"},"ai":{"faq":[{"question":"What replaces the LC1E40B10N5?","answer":"No official successor order code is recorded. The closest active sibling in the Easy TeSys family shares the same frame and mounting but may differ in coil voltage or certification revision. Verify the coil supply and ambient temperature range against your application."},{"question":"What are the key ratings for the LC1E40B10N5?","answer":"It is a 3-pole contactor rated 40 A in AC-3 (motor switching) at up to 440 V, with a 415 V AC coil. It also covers AC-3e and AC-1 utilisation categories. Standards include EN/IEC 60947-1, -4-1, -5-1, and GB/T equivalents."},{"question":"What is the mounting and size of the LC1E40B10N5?","answer":"It mounts on a plate or DIN rail. Dimensions are 56 mm wide, 84 mm high, and 86 mm deep. Non-overlap time between NC and NO contacts is 1.5 ms on both energisation and de-energisation."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E40B10N5","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E40B10N5 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}