{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E40F6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E40F6","canonicalUrl":"https://aoctrl.com/schneider/LC1E40F6","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E40F6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control, LC1E40F6, 3P contactor, AC-3/AC-3e 40A ≤440V, 110V AC 60Hz coil.","salesMarkdown":"The Schneider Electric LC1E40F6 is a 3-pole contactor from the Easy TeSys Control range, rated for AC-3 and AC-3e duty at 40 A up to 440 V, with a 110 V AC 60 Hz coil. The AC-1 rating covers resistive heating loads where the switching arc is less severe. The coil pulls in at 110 V AC, 60 Hz; verify your control transformer matches that frequency. Dimensions are 75 mm wide, 127 mm tall, 114 mm deep — fits standard 35 mm DIN-rail enclosures with room for side-by-side auxiliary blocks. ## Switching timing and mechanical robustness Mechanically rated for 1.5 Gn vibration (contacts open) and 3 Gn (closed), plus shock tolerance of 6 Gn open and 7 Gn closed. That covers most conveyor, pump, and fan applications without additional dampening. Also carries GB/T equivalents for the Chinese market. Fire resistance tested at 850 °C per IEC 60695-2-1, and the contactor meets glow-wire requirements of EN/IEC 60335-1 Clause 30.2 and EN/IEC 60335-2-40 Annex JJ — important for appliance and HVAC OEMs who need the contactor to pass the end-product glow-wire test.","metaTitle":"Schneider LC1E40F6 Easy TeSys Contactor, 40A AC-3, 110V AC C","metaDescription":"Schneider Electric LC1E40F6 Easy TeSys Control contactor. 3P, AC-3/AC-3e 40A at ≤440V, 110V AC 60Hz coil. Active production. DIN rail/plate mount. EN/IEC 60947 compliant.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"114 mm","Range":"Easy TeSys","Width":"75 mm","title":"LC1E40F6","Height":"127 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ","description":"Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3/AC-3e,<=440V,40A,110V AC coil,60Hz","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"DIN rail Plate","Non-overlap time":"1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"3P","Operating altitude":"3000 m without derating","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068-2-30 test Db","Utilisation category":"AC-3 AC-3e AC-1","Contactor application":"Motor control Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms)","IP degree of protection":"IP2X conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4c254787ce4874ea0eda9cd0a0a2c8ce.pdf","sourceUrl":"https://www.se.com/ae/en/product/LC1E40F6/contactoreasy-tesys-controllc1e3p3noac3-ac3e440v40a110v-ac-coil60hz/"},"ai":{"faq":[{"question":"What are the key ratings for the LC1E40F6?","answer":"It is a 3-pole contactor rated AC-3/AC-3e at 40 A up to 440 V, with a 110 V AC 60 Hz coil. It also carries an AC-1 rating for resistive loads. The coil is 110 V AC, 60 Hz only."},{"question":"What standards does the LC1E40F6 comply with?","answer":"It complies with EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and their GB/T equivalents. Fire resistance is tested at 850 °C per IEC 60695-2-1. It also meets glow-wire requirements of EN/IEC 60335-1 Clause 30.2 and EN/IEC 60335-2-40 Annex JJ."},{"question":"What is the physical size of the LC1E40F6?","answer":"Width 75 mm, height 127 mm, depth 114 mm. It mounts on DIN rail or directly to a panel plate."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E40F6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E40F6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}