{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E600BSCT1S260N","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E600BSCT1S260N","canonicalUrl":"https://aoctrl.com/schneider/LC1E600BSCT1S260N","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E600BSCT1S260N","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys DC contactor, LC1E600BSCT1S260N, 600 A continuous rated, 1500 V DC switching, 24 V DC coil, 1-pole normally open.","salesMarkdown":"The LC1E600BSCT1S260N: Mounts vertically on a panel or DIN rail (dedicated Easy TeSys support). Power terminals accept M8 nut with flat and spring washers; tighten to 8–10 N·m. Control wiring is a 30 cm pre-wired 2-wire supply (11.8 in). At IP60, it's sealed against dust—suitable for control cabinets but not for washdown areas. Operating temperature range -40 to 85 °C, so it lives comfortably in both hot attics and cold storage yards. ## Overload tolerance and durability Rated short-time current: 600 A continuous, 750 A for 15 minutes, 900 A for 120 seconds, and a pulse of 8000 A for 5 ms without fire or explosion—critical for surviving brief fault conditions. Mechanical life is 300,000 cycles, and it withstands 5 g vibration (10–500 Hz) and 20 g shock for 11 ms. For resistive-load switching at maximum voltage, expect 1000 cycles at 750 V / 600 A breaking and 800 cycles at 1000 V / 600 A.","metaTitle":"Schneider LC1E600BSCT1S260N DC Contactor, 600 A, 1500 V","metaDescription":"Active Easy TeSys DC contactor, 600 A resistive, 1500 V switching, 24 V coil. IEC 60947-4-1. Order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"4.09 in (104 mm)","Range":"Easy TeSys","Width":"2.8 in (70 mm)","title":"LC1E600BSCT1S260N","Height":"4.2 in (107.9 mm)","Category":"US10I1122387","Polarity":"No main contact Yes coil","Standards":"IEC 60947-4-1 GB/T 14048.4","description":"Contactor for charging post,Easy TeSys Control,DC-1 <=1500V 600A,24V DC,double coils,1NO,ceramics,internal thread,without connector","Operating time":"50 ms on closing 30 ms on opening","lifecycle_stage":"current","Mounting Support":"Vertical support","Range of Product":"Easy TeSys Control","Average impedance":"0.5 mOhm - Ith 600 A","Device short name":"LC1E","Inrush power in W":"55 W","Poles description":"1P","Tightening torque":"Power circuit 70.8...88.5 lbf.in (8...10 N.m)","Operating altitude":"13123.36 ft (4000 m) without derating","End Connection Type":"Internal Thread","Control circuit type":"DC","Contactor application":"Resistive load","Electrical durability":"1000 cycles at 750 V, 600 A on resistive load for only breaking, 0.6s open, 5.4s break 800 cycles at 1000 V, 600 A on resistive load for only breaking, 0.6s open, 5.4s break 500 cycles at 1500 V, 600 A on resistive load for only breaking, 0.6s open, 5.4s break","Insulation resistance":"1000 MOhm at 1000 V DC","Mechanical durability":"300000 cycles","Mechanical robustness":"Vibrations 5 g, 10...500 Hz) Shocks 20 g for 11 ms)","Nbr. of units in pkg.":"1","Connections - terminals":"Power circuit M8 nut Power circuit flat washers Power circuit spring washers Control circuit 2-wire supply 11.8 in (30 cm)","IP degree of protection":"IP60","Pole contact composition":"1 NO","Maximum switching voltage":"1500 V DC","Minimum switching current":"0.1 A","Minimum switching voltage":"8 V for DC","Product or Component Type":"Contactor","[Uc] control circuit voltage":"24 V DC","Auxiliary contact composition":"1 NO","Permissible short-time rating":"600 A for continuous 750 A 15 min 900 A 120 s 8000 A 5 ms (after test, No fire, No explosion)","[Ui] rated insulation voltage":"1500 V IEC 60947-4-1 power circuit","Control circuit voltage limits":"0.85...1.1 Uc operational 0.1...0.75 Uc drop-out","Hold-in power consumption in W":"5 W","Ambient air temperature for operation":"-40...185 °F (-40...85 °C) operation -40...185 °F (-40...85 °C) storage","[Uimp] rated impulse withstand voltage":"8 kV coil not connected to the power circuit IEC 60947","[Ith] conventional free air thermal current":"600 A for power circuit"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,000.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9dfcf3249996fbb51fa92122fa058b6e.pdf","sourceUrl":"https://www.se.com/us/en/product/LC1E600BSCT1S260N/contactor-for-charging-posteasy-tesys-controldc1-1500v-600a24v-dcdouble-coils1noceramicsinternal-threadwithout-connector/"},"ai":{"faq":[{"question":"What is the maximum DC switching voltage?","answer":"1500 V DC, rated for resistive load breaking."},{"question":"What compliance standards does it meet?","answer":"It complies with IEC 60947-4-1 and GB/T 14048.4, and carries an impulse withstand voltage of 8 kV (coil not connected to power circuit)."},{"question":"What is the depth of this contactor?","answer":"Listed depth is 4.09 in (104 mm)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E600BSCT1S260N","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E600BSCT1S260N when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}