{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E65008M5WBIN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E65008M5WBIN","canonicalUrl":"https://aoctrl.com/schneider/LC1E65008M5WBIN","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E65008M5WBIN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control LC1E65008M5WBIN, 4-pole contactor, 85 A rated operational current (AC-1 at ≤415 V), 220 V AC 50 Hz coil, screw clamp terminals, DIN rail or plate mount.","salesMarkdown":"## Spec and fit for the BOM line The LC1E65008M5WBIN is a 4-pole contactor from the Schneider Electric Easy TeSys Control range, rated for 85 A in AC-1 utilisation category at ≤415 V AC. That 85 A figure governs resistive loads — heaters, ovens, lighting banks — not motor starting. The 220 V AC 50 Hz coil is a wide-range control circuit type, so it pulls in reliably between 0.7 and 1.25 Uc and drops out between 0.3 and 0.6 Uc across -5 to 55 °C. Pole configuration is 2 NO + 2 NC with no auxiliary contacts built in — if your circuit needs aux switching, you add a separate block. Dimensions are 85 mm wide, 127 mm high, 125 mm deep — that depth matters when you are laying out a shallow enclosure. Power circuit terminals accept 2.5 to 25 mm² flexible with cable end (or solid up to 25 mm²); control circuit terminals take 1 to 4 mm². Tighten the power terminals to 5 N.m, control terminals to 1.2 N.m. No special torque driver needed, but a calibrated screwdriver keeps connection resistance repeatable. Heat dissipation runs 6 to 10 W through the control circuit, plus 6.4 W per pole in AC-1 duty. Average impedance per pole is 1 mOhm at 85 A 50 Hz. ## Durability and switching performance Mechanical life is rated at 5 million cycles; electrical endurance at 350,000 cycles under AC-1 conditions. Maximum operating rate is 1200 cycles per hour at 60 °C. Closing time is 20 to 26 ms, opening 8 to 12 ms — fast enough for most on/off resistive switching, not intended for high-speed chopping. Rated making capacity is 650 A at 440 V AC; breaking capacity is 520 A at 440 V. The associated fuse recommendation is 125 A gG at ≤690 V, coordination type 1, so the fuse clears before the contactor welds on a bolted fault. Vibration resistance is 1.5 Gn (open) and 3 Gn (closed) over 5 to 300 Hz; shock resistance is 6 Gn (open) and 7 Gn (closed) for 11 ms. That is adequate for most industrial panel environments but not for direct mounting on a reciprocating compressor or engine block.","metaTitle":"LC1E65008M5WBIN Easy TeSys Contactor, 85 A AC-1, 220 V AC Co","metaDescription":"Schneider Electric LC1E65008M5WBIN Easy TeSys contactor, 4-pole, 85 A rated operational current at ≤415 V AC AC-1, 220 V AC 50 Hz coil. Current lifecycle stage. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"125 mm","Range":"Easy TeSys","Width":"85 mm","Height":"127 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5","Operating time":"20...26 ms on closing 8...12 ms on opening","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Heat dissipation":"6...10 W for control circuit","Mounting support":"DIN rail Plate","Pollution degree":"3","Range of product":"Easy TeSys Control","Average impedance":"1 mOhm - Ith 85 A 50 Hz for power circuit","Device short name":"LC1E","Poles description":"4P","Tightening torque":"Control circuit: 1.2 N.m Power circuit: 5 N.m","Inrush power in VA":"160 VA 50 Hz cos phi 0.75 (at 20 °C)","Operating altitude":"3000 m","Control circuit type":"AC at 50 Hz wide range","Overvoltage category":"III","Protective treatment":"TH conforming to IEC 60068","Utilisation category":"AC-1","Contactor application":"Resistive load","Electrical durability":"350000 cycles AC-1","Mechanical durability":"5000000 cycles","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms)","Associated fuse rating":"125 A gG at <= 690 V coordination type 1 for power circuit","Maximum operating rate":"1200 cyc/h 60 °C","Connections - terminals":"Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1...2.5 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 2.5...25 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 2.5...10 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: solid Control circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: solid Power circuit: screw clamp terminals 1 2.5...25 mm² - cable stiffness: solid Power circuit: screw clamp terminals 2 2.5...16 mm² - cable stiffness: solid","IP degree of protection":"IP20 conforming to IEC 60529","Rated breaking capacity":"520 A at 440 V for power circuit conforming to IEC 60947","Pole contact composition":"2 NO + 2 NC","Product or component type":"Contactor","Irms rated making capacity":"650 A at 440 V AC for power circuit conforming to IEC 60947-4-1","Power dissipation per pole":"6.4 W AC-1","[Uc] control circuit voltage":"220 V AC 50 Hz","Auxiliary contact composition":"Without","[Ui] rated insulation voltage":"690 V conforming to IEC 60947-4-1","Control circuit voltage limits":"0.3...0.6 Uc (-5...55 °C):drop-out 50 Hz 0.7...1.25 Uc (-5...55 °C):operational 50 Hz","[Ie] rated operational current":"85 A (at <40 °C) at <= 415 V AC AC-1 for power circuit","[Ue] rated operational voltage":"Power circuit: <= 690 V AC 50/60 Hz","Hold-in power consumption in VA":"15 VA 50 Hz cos phi 0.3 (at 20 °C)","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947","[Icw] rated short-time withstand current":"520 A 40 °C - 10 s for power circuit 260 A 40 °C - 60 s for power circuit 110 A 40 °C - 600 s for power circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/LC1E65008M5WBIN/easy-tesys-contactor-4p4-no-ac1-415-v-60a-415-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E65008M5WBIN/alternatives.json"},"ai":{"faq":[{"question":"What is the depth of the LC1E65008M5WBIN?","answer":"The depth is 125 mm. Combined with the 85 mm width and 127 mm height, it fits standard DIN-rail spacing but requires 125 mm of enclosure depth clearance."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E65008M5WBIN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E65008M5WBIN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}