{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E80004M5WB","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E80004M5WB","canonicalUrl":"https://aoctrl.com/schneider/LC1E80004M5WB","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E80004M5WB","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control LC1E80004M5WB, 4-pole contactor, 100 A AC-1, 220 V AC 50 Hz coil, IP20.","salesMarkdown":"The contactor is configured with 4 normally open (NO) main poles and no built-in auxiliary contacts, so plan on adding a separate auxiliary block if you need feedback or interlocking. The coil is a wide-range AC type, specified at 220 V AC 50 Hz. Pull-in power is 200 VA at 50 Hz (cos φ 0.75 at 20 °C), and steady-state heat dissipation in the control circuit runs 6 to 10 W. The coil holds in reliably from 0.7 to 1.25 Uc across -5 to 55 °C, and drops out between 0.3 and 0.6 Uc. Opening time is 6 to 20 ms; closing time is 20 to 35 ms. These timing windows matter if you're sequencing contactors in a transfer scheme — the spread is wide enough that you can't rely on millisecond-level coordination without external timing. Mounts on either a plate or a DIN rail. Power circuit terminals accept screw-clamp connections from 4 to 50 mm² (flexible with cable end) or 4 to 50 mm² solid, with a tightening torque of 12 N·m. Control circuit terminals take 1 to 4 mm² at 1.2 N·m. The IP20 finger-safe enclosure is standard for panel-mount contactors; no washdown rating here, so keep it inside the cabinet. The contactor also carries a TH protective treatment per IEC 60068-2-30 for damp-heat environments. Associated fuse rating for type 1 coordination is 160 A gG at ≤690 V. ## Durability and operating limits Mechanical durability is rated at 3 million cycles; electrical durability under AC-1 is 350,000 cycles. Maximum operating rate is 1200 cycles per hour at 60 °C. Vibration resistance is 1.5 Gn (contactor open) and 3 Gn (closed) over 5 to 300 Hz; shock resistance is 6 Gn for 11 ms (open) and 7 Gn for 11 ms (closed). These figures are solid for general industrial panel duty but not for high-vibration mobile equipment.","metaTitle":"Schneider LC1E80004M5WB Easy TeSys Contactor, 100 A AC-1, 4","metaDescription":"Schneider Electric LC1E80004M5WB contactor from the Easy TeSys range. Rated 100 A AC-1 at ≤440 V, 4 NO main poles, 220 V AC 50 Hz coil. Current lifecycle stage. IP20. Sourced to or","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"120 mm","Range":"Easy TeSys","Width":"95 mm","Height":"127 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5","Operating time":"6...20 ms on opening 20...35 ms on closing","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Heat dissipation":"6...10 W for control circuit","Mounting support":"Plate DIN rail","Pollution degree":"3","Range of product":"Easy TeSys Control","Average impedance":"0.8 mOhm - Ith 100 A 50 Hz for power circuit","Device short name":"LC1E","Poles description":"4P","Tightening torque":"Control circuit: 1.2 N.m Power circuit: 12 N.m","Inrush power in VA":"200 VA 50 Hz cos phi 0.75 (at 20 °C)","Operating altitude":"3000 m without derating","Control circuit type":"AC at 50 Hz wide range","Overvoltage category":"III","Protective treatment":"TH conforming to IEC 60068-2-30 test Db","Utilisation category":"AC-1","Contactor application":"Resistive load","Electrical durability":"350000 cycles AC-1","Mechanical durability":"3000000 cycles","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms)","Associated fuse rating":"160 A gG at <= 690 V coordination type 1 for power circuit","Maximum operating rate":"1200 cyc/h 60 °C","Connections - terminals":"Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1...2.5 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 4...50 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 4...16 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: solid Control circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: solid Power circuit: screw clamp terminals 1 4...50 mm² - cable stiffness: solid Power circuit: screw clamp terminals 2 4...50 mm² - cable stiffness: solid","IP degree of protection":"IP20 conforming to IEC 60529","Rated breaking capacity":"640 A at 440 V for power circuit conforming to IEC 60947","Pole contact composition":"4 NO","Product or component type":"Contactor","Irms rated making capacity":"800 A at 440 V AC for power circuit conforming to IEC 60947-4-1","Power dissipation per pole":"9.7 W AC-1","[Uc] control circuit voltage":"220 V AC 50 Hz","Auxiliary contact composition":"Without","[Ui] rated insulation voltage":"690 V conforming to IEC 60947-4-1","Control circuit voltage limits":"0.3...0.6 Uc (-5...55 °C):drop-out 50 Hz 0.7...1.25 Uc (-5...55 °C):operational 50 Hz","[Ie] rated operational current":"100 A (at <55 °C) at <= 440 V AC AC-1 for power circuit","[Ue] rated operational voltage":"Power circuit: <= 690 V AC 50/60 Hz","Hold-in power consumption in VA":"20 VA 50 Hz cos phi 0.3 (at 20 °C)","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947","[Icw] rated short-time withstand current":"640 A 40 °C - 10 s for power circuit 320 A 40 °C - 60 s for power circuit 135 A 40 °C - 600 s for power circuit","[Ith] conventional free air thermal current":"100 A (at 55 °C) for power circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c3e9d321523e42ad6a21ac2d93a4eb3b.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC1E80004M5WB/contactoreasy-tesys-controllc1e4p4noac1-100a220v50hz-wide-range/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E80004M5WB/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to LC1E80004M5WB in the Easy TeSys family?","answer":"Within the same Easy TeSys Control range, the closest functional alternative would be a 4-pole contactor with the same 100 A AC-1 rating and 220 V AC coil. The key difference to check is the pole configuration — this unit has 4 NO poles with no auxiliary contacts. If you need a different coil voltage or an auxiliary contact block, that's a separate variant within the LC1E family."},{"question":"What are the key ratings for this contactor?","answer":"Rated operational current (Ie) is 100 A at ≤440 V AC in AC-1 duty. Rated insulation voltage (Ui) is 690 V. Control circuit voltage (Uc) is 220 V AC 50 Hz. Breaking capacity is 640 A at 440 V; making capacity is 800 A at 440 V AC. Associated fuse is 160 A gG at ≤690 V for type 1 coordination."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E80004M5WB","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E80004M5WB when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}