{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E80004N5WBIN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E80004N5WBIN","canonicalUrl":"https://aoctrl.com/schneider/LC1E80004N5WBIN","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E80004N5WBIN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control, contactor LC1E80004N5WBIN, 4-pole, 4 NO, 110 A AC-1 at ≤415 VAC, 415 VAC 50 Hz coil, DIN rail/plate mount.","salesMarkdown":"It is rated to carry 110 A continuously at ≤415 V AC (AC-1) with all four poles normally open (4 NO). The control circuit is a wide-range AC coil at 415 V 50 Hz, with pull-in voltage between 0.7 and 1.25 Uc and drop-out between 0.3 and 0.6 Uc across -5 to 55 °C. The 95 mm width and 127 mm height keep the footprint compact for a 4-pole 110 A contactor. IP20 finger-safe protection covers the terminals for panel-side safety. Screw-clamp power terminals accept solid or flexible cable up to 50 mm² — enough for the 110 A feed without needing a lug adapter. Tighten power connections to 12 N·m; control wiring to 1.2 N·m. AC-1 is the thermal current (Ith) at 40 °C ambient; for motor duty (AC-3) you would need a different frame. The 4 NO pole arrangement gives four independently switched lines, common for three-phase plus neutral or two separate resistive circuits. Electrical durability of 350,000 cycles at AC-1 and mechanical durability of 3 million cycles tell you the contactor is built for high-cycle applications like conveyor ovens or packaging-line heaters. The 6–10 W heat dissipation from the control circuit matters for enclosure thermal budgeting — at 110 A load, the power poles add about 9.7 W per pole, so total dissipation can reach roughly 45 W in a sealed cabinet.","metaTitle":"Schneider LC1E80004N5WBIN Easy TeSys Contactor, 110 A AC-1,","metaDescription":"Schneider Electric Easy TeSys LC1E80004N5WBIN 4-pole contactor, 110 A AC-1 at 415 VAC, 4 NO, 415 VAC 50 Hz coil. Active production. DIN rail/plate mount. EN/IEC 60947 compliant. So","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"120 mm","Range":"Easy TeSys","Width":"95 mm","Height":"127 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5","Operating time":"6...20 ms on opening 20...35 ms on closing","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Heat dissipation":"6...10 W for control circuit","Mounting support":"DIN rail Plate","Pollution degree":"3","Range of product":"Easy TeSys Control","Average impedance":"0.8 mOhm - Ith 110 A 50 Hz for power circuit","Device short name":"LC1E","Poles description":"4P","Tightening torque":"Control circuit: 1.2 N.m Power circuit: 12 N.m","Inrush power in VA":"200 VA 50 Hz cos phi 0.75 (at 20 °C)","Operating altitude":"3000 m","Control circuit type":"AC at 50 Hz wide range","Overvoltage category":"III","Protective treatment":"TH conforming to IEC 60068","Utilisation category":"AC-1","Contactor application":"Resistive load","Electrical durability":"350000 cycles AC-1","Mechanical durability":"3000000 cycles","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms)","Associated fuse rating":"160 A gG at <= 690 V coordination type 1 for power circuit","Maximum operating rate":"1200 cyc/h 60 °C","Connections - terminals":"Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1...2.5 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 4...50 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 4...16 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: solid Control circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: solid Power circuit: screw clamp terminals 1 4...50 mm² - cable stiffness: solid Power circuit: screw clamp terminals 2 4...50 mm² - cable stiffness: solid","IP degree of protection":"IP20 conforming to IEC 60529","Rated breaking capacity":"640 A at 440 V for power circuit conforming to IEC 60947","Pole contact composition":"4 NO","Product or component type":"Contactor","Irms rated making capacity":"800 A at 440 V AC for power circuit conforming to IEC 60947-4-1","Power dissipation per pole":"9.7 W AC-1","[Uc] control circuit voltage":"415 V AC 50 Hz","Auxiliary contact composition":"Without","[Ui] rated insulation voltage":"690 V conforming to IEC 60947-4-1","Control circuit voltage limits":"0.3...0.6 Uc (-5...55 °C):drop-out 50 Hz 0.7...1.25 Uc (-5...55 °C):operational 50 Hz","[Ie] rated operational current":"110 A (at <40 °C) at <= 415 V AC AC-1 for power circuit","[Ue] rated operational voltage":"Power circuit: <= 690 V AC 50/60 Hz","Hold-in power consumption in VA":"20 VA 50 Hz cos phi 0.3 (at 20 °C)","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947","[Icw] rated short-time withstand current":"640 A 40 °C - 10 s for power circuit 320 A 40 °C - 60 s for power circuit 135 A 40 °C - 600 s for power circuit","[Ith] conventional free air thermal current":"110 A (at 40 °C) for power circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/792dbd7947558eb7f2f4023028a63793.pdf","sourceUrl":"https://www.se.com/in/en/product/LC1E80004N5WBIN/easy-tesys-contactor-4p2-no-+-2-nc-ac1-415-v-60a-380-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E80004N5WBIN/alternatives.json"},"ai":{"faq":[{"question":"What is the closest pin-compatible alternative in this family?","answer":"Within the Easy TeSys Control range, the LC1E80004N5WBIN is a specific variant defined by its 415 V 50 Hz coil voltage and 4 NO pole arrangement. There is no pin-compatible alternative that differs only by coil voltage — if the coil voltage matches, the part is the same. For a different coil voltage, the order code changes."},{"question":"What is the rated operational current and what does AC-1 mean?","answer":"It is rated 110 A at ≤415 V AC under AC-1 utilisation category. AC-1 covers resistive loads (heaters, ovens) — not motor starting. For motor loads you would need a contactor rated in AC-3."},{"question":"What compliance standards does it meet?","answer":"It complies with EN/IEC 60947-1 (general rules), EN/IEC 60947-4-1 (contactors and motor-starters), EN/IEC 60947-5-1 (control-circuit devices), and their Chinese GB/T equivalents. It also meets overvoltage category III and pollution degree 3 per IEC 60947."},{"question":"What is the mounting and terminal specification?","answer":"Mounts on DIN rail or plate. Power terminals accept solid or flexible cable up to 50 mm²; control terminals accept up to 4 mm². Tighten power connections to 12 N·m, control to 1.2 N·m."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E80004N5WBIN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E80004N5WBIN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}