{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E80008Q7IN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E80008Q7IN","canonicalUrl":"https://aoctrl.com/schneider/LC1E80008Q7IN","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E80008Q7IN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control, LC1E80008Q7IN, 4-pole contactor, AC-1 110A at 415V, 95 x 127 x 120 mm, obsolete.","salesMarkdown":"The Schneider Electric LC1E80008Q7IN is a 4-pole contactor from the Easy TeSys Control range, rated for AC-1 resistive loads up to 110 A at 415 V. With a 4P configuration (2NO+2NC), it's built for switching resistive heating elements, lighting banks, or other non-inductive loads in industrial control panels. The 95 x 127 x 120 mm footprint fits standard DIN rail or plate mounting, and the IP2X finger-safe enclosure meets basic touch protection requirements. The AC-1 utilisation category is the headline rating here — 110 A at 415 V. AC-1 covers resistive loads where the current inrush is minimal, so this contactor is not suited for motor starting (that would be AC-3 duty). If your BOM calls for switching resistive banks, this rating confirms the thermal capacity. The 4-pole arrangement with two normally-open and two normally-closed contacts gives flexibility for multi-circuit isolation or interlocking without adding auxiliary blocks. Environmental robustness includes an operating altitude up to 3000 m, protective treatment TH (pollution degree 3) for humid or mildly corrosive atmospheres, and vibration/shock ratings of 1.5 Gn open / 3 Gn closed for vibration and 6 Gn open / 7 Gn closed for shock. The permissible ambient temperature spans -20 to 70 °C at the coil, with storage down to -60 °C and operation from -5 to 55 °C. These specs mean it holds up in unheated enclosures or near process heat, as long as the coil voltage stays within the rated range. The LC1E80008Q7IN complies with EN/IEC 60947-1, EN/IEC 60947-4-1, and EN/IEC 60947-5-1, plus the Chinese GB/T equivalents. These certifications cover the contactor for use in industrial control equipment across most global markets, including CE-marked installations.","metaTitle":"Schneider LC1E80008Q7IN Easy TeSys Contactor, 4P, 110A AC-1,","metaDescription":"Schneider Electric LC1E80008Q7IN Easy TeSys Control contactor, 4P (2NO+2NC), AC-1 110A at 415V. Obsolete per manufacturer. Sourced to order against RFQ. DIN rail/plate mount, 95x12","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"120 mm","Range":"Easy TeSys","Width":"95 mm","Height":"127 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"Plate DIN rail","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"4P","Operating altitude":"3000 m","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068","Utilisation category":"AC-1","Contactor application":"Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms)","IP degree of protection":"IP2X conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/339ddf0d0d73e3f9b787d38903c83e24.pdf","sourceUrl":"https://www.se.com/sg/en/product/LC1E80008Q7IN/contactoreasy-tesys-controllc1e4p2no+2ncac1415v110a380v/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E80008Q7IN/alternatives.json"},"ai":{"faq":[{"question":"What are the key dimensions for panel fit?","answer":"The contactor measures 95 mm wide, 127 mm high, and 120 mm deep. It mounts on either a DIN rail or a plate."},{"question":"What is the utilisation category and what loads does it suit?","answer":"It is rated AC-1 for resistive loads up to 110 A at 415 V. Use it for switching heaters, lighting, or other non-inductive circuits — not for motor starting."},{"question":"What compliance standards does it meet?","answer":"It complies with EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and the Chinese GB/T 14048 series. Fire resistance is certified to 850 °C per IEC 60695-2-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E80008Q7IN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E80008Q7IN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}