{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E80M6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E80M6","canonicalUrl":"https://aoctrl.com/schneider/LC1E80M6","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E80M6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control, LC1E80M6, 3P(3NO) contactor, AC-3 ≤440V 80A, 220V AC coil 60Hz.","salesMarkdown":"The Schneider Electric LC1E80M6 is a 3-pole contactor from the Easy TeSys Control range, rated for 80 A in AC-3 duty at ≤440 V, with a 220 V AC 60 Hz coil. That AC-3 rating means it's sized for starting and stopping squirrel-cage induction motors under load — the most common contactor job in a control panel. It also carries AC-3e and AC-1 utilisation categories, so it handles motor starts with extended electrical life (AC-3e) and resistive heating loads (AC-1) without derating. The contactor mounts on either a DIN rail or a plate, giving panel builders flexibility on layout. This contactor is rated for operation up to 3000 m altitude without derating, and the TH protective treatment (pollution degree 3 per IEC 60068-2-30) means it's built for humid, mildly corrosive environments — think HVAC plant rooms, pump houses, or unheated warehouses. Mechanical robustness is specified at 1.5 Gn vibration (contacts open) and 3 Gn (closed), plus shock ratings of 6 Gn open and 7 Gn closed — enough for most industrial machinery but not for direct engine-mount on a genset. It complies with EN/IEC 60947-1, 60947-4-1, and 60947-5-1, plus GB/T equivalents for the Chinese market. It also meets EN/IEC 60335-1 Clause 30.2 and 60335-2-40 Annex JJ for appliance and HVAC applications.","metaTitle":"Schneider Electric LC1E80M6 Easy TeSys Contactor, 80A AC-3,","metaDescription":"Active LC1E80M6 contactor from Schneider Electric Easy TeSys Control series. 80A AC-3 motor switching, 220VAC 60Hz coil, 3P. DIN rail/plate mount. EN/IEC 60947 compliant. Sourced t","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"121 mm","Range":"Easy TeSys","Width":"85 mm","title":"LC1E80M6","Height":"127 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ","description":"Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3,<=440V,80A,220V AC coil,60Hz","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"Plate DIN rail","Non-overlap time":"1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"3P","Operating altitude":"3000 m without derating","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068-2-30","Utilisation category":"AC-3 AC-3e AC-1","Contactor application":"Motor control Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms)","IP degree of protection":"IP2X conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/114495012482424eec01991bf17e4b1c.pdf","sourceUrl":"https://www.se.com/sa/en/product/LC1E80M6/contactoreasy-tesys-controllc1e3p3noac3440v80a220v-ac-coil60hz/"},"ai":{"faq":[{"question":"What are the key electrical ratings for this contactor?","answer":"The LC1E80M6 is rated 80 A in AC-3 utilisation category at ≤440 V, with a 220 V AC 60 Hz coil. It also covers AC-3e and AC-1 categories, meaning it handles motor starting, extended electrical-life motor starting, and resistive loads."},{"question":"What mounting options does the LC1E80M6 support?","answer":"It mounts on either a DIN rail or a plate, giving flexibility for panel layout. Dimensions are 85 mm wide, 127 mm high, and 121 mm deep."},{"question":"What standards does the LC1E80M6 comply with?","answer":"It complies with EN/IEC 60947-1, 60947-4-1, and 60947-5-1, plus GB/T 14048.1, 14048.4, and 14048.5. It also meets EN/IEC 60335-1 Clause 30.2 and 60335-2-40 Annex JJ for appliance and HVAC applications."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E80M6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E80M6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}