{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E95004N5WB","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E95004N5WB","canonicalUrl":"https://aoctrl.com/schneider/LC1E95004N5WB","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E95004N5WB","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control contactor, LC1E95004N5WB, 4-pole, 125 A AC-1, 415 VAC 50 Hz coil, screw clamp terminals, IP20, DIN rail/plate mount.","salesMarkdown":"The Schneider Electric LC1E95004N5WB is a 4-pole contactor from the Easy TeSys Control range, rated for 125 A in AC-1 duty at up to 440 V — that is the resistive-load rating, so it handles heater banks, lighting, or transformer primaries where inrush is modest. The coil is 415 V AC 50 Hz, wide-range tolerance, with a drop-out band of 0.3 to 0.6 Uc and pick-up from 0.7 to 1.25 Uc across -5 to 55 °C. Mounts on DIN rail or a plate, IP20 finger-safe, so it goes into a standard control panel without special sealing. The headline 125 A at 440 V AC-1 is the continuous resistive current — not a motor-starting figure. If you are switching a motor load, you need the AC-3 rating (not listed here), so this part is sized for resistive banks or distribution, not induction motors. The 4 NO pole composition means all four poles switch the line; no auxiliary contacts are built in, so plan for a separate auxiliary block if you need feedback to a PLC. Breaking capacity is 760 A at 440 V, and making capacity is 950 A — both per IEC 60947, so it clears fault currents without welding contacts under normal conditions. Screw clamp terminals on both power and control circuits. Power side accepts 4 to 50 mm² solid or flexible with ferrule; control side takes 1 to 4 mm². Tightening torque is 12 N·m on power, 1.2 N·m on control — a torque screwdriver is needed to avoid terminal damage. The 95 mm width and 135 mm depth mean it occupies roughly three 18 mm DIN-module spaces; plan panel layout accordingly. Heat dissipation is 6 to 10 W on the control circuit and 12 W per pole on AC-1, so ensure ventilation or spacing in a dense enclosure.","metaTitle":"Schneider Electric LC1E95004N5WB Easy TeSys Contactor, 125 A","metaDescription":"Schneider Electric LC1E95004N5WB Easy TeSys contactor, 125 A AC-1 at 440 V, 4 NO poles, 415 VAC 50 Hz coil, IP20, DIN rail mount. Current lifecycle stage. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"135 mm","Range":"Easy TeSys","Width":"95 mm","Height":"127 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5","Operating time":"6...20 ms on opening 20...35 ms on closing","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Heat dissipation":"6...10 W for control circuit","Mounting support":"Plate DIN rail","Pollution degree":"3","Range of product":"Easy TeSys Control","Average impedance":"0.8 mOhm - Ith 125 A 50 Hz for power circuit","Device short name":"LC1E","Poles description":"4P","Tightening torque":"Control circuit: 1.2 N.m Power circuit: 12 N.m","Inrush power in VA":"200 VA 50 Hz cos phi 0.75 (at 20 °C)","Operating altitude":"3000 m without derating","Control circuit type":"AC at 50 Hz wide range","Overvoltage category":"III","Protective treatment":"TH conforming to IEC 60068-2-30","Utilisation category":"AC-1","Contactor application":"Resistive load","Electrical durability":"350000 cycles AC-1","Mechanical durability":"3000000 cycles","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms)","Associated fuse rating":"160 A gG at <= 690 V coordination type 1 for power circuit","Maximum operating rate":"1200 cyc/h 60 °C","Connections - terminals":"Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1...2.5 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 4...50 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 4...16 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: solid Control circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: solid Power circuit: screw clamp terminals 1 4...50 mm² - cable stiffness: solid Power circuit: screw clamp terminals 2 4...50 mm² - cable stiffness: solid","IP degree of protection":"IP20 conforming to IEC 60529","Rated breaking capacity":"760 A at 440 V for power circuit conforming to IEC 60947","Pole contact composition":"4 NO","Product or component type":"Contactor","Irms rated making capacity":"950 A at 440 V AC for power circuit conforming to IEC 60947-4-1","Power dissipation per pole":"12 W AC-1","[Uc] control circuit voltage":"415 V AC 50 Hz","Auxiliary contact composition":"Without","[Ui] rated insulation voltage":"690 V conforming to IEC 60947-4-1","Control circuit voltage limits":"0.3...0.6 Uc (-5...55 °C):drop-out 50 Hz 0.7...1.25 Uc (-5...55 °C):operational 50 Hz","[Ie] rated operational current":"125 A (at <55 °C) at <= 440 V AC AC-1 for power circuit","[Ue] rated operational voltage":"Power circuit: <= 690 V AC 50/60 Hz","Hold-in power consumption in VA":"20 VA 50 Hz cos phi 0.3 (at 20 °C)","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947","[Icw] rated short-time withstand current":"135 A 40 °C - 600 s for power circuit 800 A 40 °C - 10 s for power circuit 400 A 40 °C - 60 s for power circuit","[Ith] conventional free air thermal current":"125 A (at 55 °C) for power circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3c33359b7f3e50542c9d5eef784fdfa5.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC1E95004N5WB/contactoreasy-tesys-controllc1e4p4noac1-125a415v50hz-wide-range/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E95004N5WB/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to this contactor in the Easy TeSys range?","answer":"The LC1E95004N5WB is a 4-pole, 125 A AC-1 contactor with a 415 V AC 50 Hz coil. A direct sibling would share the same pole count and AC-1 rating but differ in coil voltage — for example, a 230 V coil variant. No pin-compatible drop-in exists with a different coil voltage; the coil is the only variable that changes fit in the same frame size."},{"question":"What compliance documentation is available for this part?","answer":"The contactor is certified to EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and the Chinese GB/T equivalents. It carries IP20 protection per IEC 60529, and the protective treatment is TH per IEC 60068-2-30 (tropicalized). Fire resistance is 850 °C per IEC 60695-2-1. RoHS and REACH declarations are standard for Schneider's current-production Easy TeSys range."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E95004N5WB","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E95004N5WB when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}