{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E95008N5WB","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E95008N5WB","canonicalUrl":"https://aoctrl.com/schneider/LC1E95008N5WB","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E95008N5WB","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control LC1E95008N5WB, 4-pole contactor, 125 A AC-1 at ≤440 V, 415 VAC 50 Hz coil, screw clamp terminals, IP20.","salesMarkdown":"The 415 V AC 50 Hz coil is a wide-range AC type, meaning it pulls in reliably across a band of control voltages, not just a single tap. That covers the main power switching standard (60947-4-1) and the control-circuit standard (60947-5-1), so it fits panels destined for European or Chinese-certified machinery. The 125 A AC-1 rating is the headline number, but note it is at ≤55 °C and ≤440 V — the AC-1 category means resistive load, not motor starting. For motor duty (AC-3) you would need to derate significantly; this contactor is not specified for AC-3. The 4-pole arrangement is 2 NO + 2 NC, giving you both normally-open and normally-closed power poles, which is useful for reversing or two-speed circuits where one set of poles breaks before the other makes. Mechanical durability is rated at 3,000,000 cycles, and electrical durability at 350,000 cycles under AC-1. That is a solid service life for a resistive-load contactor that cycles a few times per hour. The maximum operating rate is 1,200 cycles per hour at 60 °C, so it can keep pace with a fast-cycling oven or packaging line heater bank. The control circuit dissipates 6 to 10 W and has an inrush of 200 VA at 50 Hz (cos φ 0.75). That matters for transformer sizing in the control panel — a 200 VA inrush spike means the control transformer should be rated to handle that surge without dropping the coil voltage below the 0.7 Uc operational limit. Mounts on plate or DIN rail; the screw-clamp power terminals accept up to 50 mm² cable, which is what you would expect for a 125 A circuit.","metaTitle":"Schneider Electric LC1E95008N5WB Easy TeSys Contactor, 125 A","metaDescription":"Schneider Electric LC1E95008N5WB Easy TeSys contactor, 125 A AC-1 at 440 V, 4-pole, 415 VAC 50 Hz coil. Active production. Sourced to order. Standards: EN/IEC 60947.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"135 mm","Range":"Easy TeSys","Width":"95 mm","Height":"127 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5","Operating time":"6...20 ms on opening 20...35 ms on closing","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Heat dissipation":"6...10 W for control circuit","Mounting support":"Plate DIN rail","Pollution degree":"3","Range of product":"Easy TeSys Control","Average impedance":"0.8 mOhm - Ith 125 A 50 Hz for power circuit","Device short name":"LC1E","Poles description":"4P","Tightening torque":"Control circuit: 1.2 N.m Power circuit: 12 N.m","Inrush power in VA":"200 VA 50 Hz cos phi 0.75 (at 20 °C)","Operating altitude":"3000 m without derating","Control circuit type":"AC at 50 Hz wide range","Overvoltage category":"III","Protective treatment":"TH conforming to IEC 60068-2-30","Utilisation category":"AC-1","Contactor application":"Resistive load","Electrical durability":"350000 cycles AC-1","Mechanical durability":"3000000 cycles","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms)","Associated fuse rating":"160 A gG at <= 690 V coordination type 1 for power circuit","Maximum operating rate":"1200 cyc/h 60 °C","Connections - terminals":"Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1...2.5 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 4...50 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 4...16 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: solid Control circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: solid Power circuit: screw clamp terminals 1 4...50 mm² - cable stiffness: solid Power circuit: screw clamp terminals 2 4...50 mm² - cable stiffness: solid","IP degree of protection":"IP20 conforming to IEC 60529","Rated breaking capacity":"760 A at 440 V for power circuit conforming to IEC 60947","Pole contact composition":"2 NO + 2 NC","Product or component type":"Contactor","Irms rated making capacity":"950 A at 440 V AC for power circuit conforming to IEC 60947-4-1","Power dissipation per pole":"12 W AC-1","[Uc] control circuit voltage":"415 V AC 50 Hz","Auxiliary contact composition":"Without","[Ui] rated insulation voltage":"690 V conforming to IEC 60947-4-1","Control circuit voltage limits":"0.3...0.6 Uc (-5...55 °C):drop-out 50 Hz 0.7...1.25 Uc (-5...55 °C):operational 50 Hz","[Ie] rated operational current":"125 A (at <55 °C) at <= 440 V AC AC-1 for power circuit","[Ue] rated operational voltage":"Power circuit: <= 690 V AC 50/60 Hz","Hold-in power consumption in VA":"20 VA 50 Hz cos phi 0.3 (at 20 °C)","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947","[Icw] rated short-time withstand current":"135 A 40 °C - 600 s for power circuit 800 A 40 °C - 10 s for power circuit 400 A 40 °C - 60 s for power circuit","[Ith] conventional free air thermal current":"125 A (at 55 °C) for power circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2b0c397ce0d21936daaa9f46653ce90c.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC1E95008N5WB/contactoreasy-tesys-controllc1e4p2no+2ncac1-125a415v50hz-wide-range/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E95008N5WB/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings of the LC1E95008N5WB?","answer":"It is a 4-pole contactor rated 125 A AC-1 at ≤440 V, with a 415 V AC 50 Hz coil. Rated insulation voltage is 690 V. Mechanical durability is 3,000,000 cycles; electrical durability under AC-1 is 350,000 cycles."},{"question":"What standards does the LC1E95008N5WB comply with?","answer":"It complies with EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and the Chinese GB/T 14048.1, GB/T 14048.4, and GB/T 14048.5."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E95008N5WB","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E95008N5WB when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}