{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1F1000FD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1F1000FD","canonicalUrl":"https://aoctrl.com/schneider/LC1F1000FD","factsUrl":"https://aoctrl.com/api/mcp/products/LC1F1000FD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F LC1F1000FD, 3-pole contactor, 1250 A AC-3 rated operational current, 110 V DC coil, plate mount, end-of-life status.","salesMarkdown":"The Schneider Electric TeSys F LC1F1000FD is a 3-pole direct on-line contactor rated for heavy motor control and resistive loads. It carries a rated operational current of 1250 A in AC-3 duty (motor switching) at <= 440 V AC, and a conventional free air thermal current of 1250 A at 40 °C. The coil is 110 V DC standard. Rated breaking capacity is 8 kA per IEC 60947-4-1, and the short-time withstand current is 10 kA for 10 seconds at 40 °C — enough to coordinate with upstream 1400 A gG fuses at <= 440 V. The contactor is designed for plate mounting, not DIN rail, so factor in panel layout accordingly. ## Motor power and duty cycle This contactor handles 315 kW at 220–230 V three-phase, 560 kW at 380–400 V, 630 kW at 415 V, and 670 kW at 440 V. That puts it squarely in the large-motor class — think big pumps, compressors, or conveyor drives on 400 V class systems. Maximum operating rate is 600 cycles per hour at 55 °C. ## Lifecycle reality — end of life This part carries an end-of-life (EOL) status. Schneider has discontinued the LC1F1000FD. Sourcing is through last-time-buy or surplus channels. The LC1F1000FD is designed and certified to EN 60947-4-1 and IEC 60947-4-1 (the contactor standard), plus EN/IEC 60947-1 (general rules). Rated insulation voltage is 1000 V per IEC 60947-4-1, with an impulse withstand voltage of 8 kV. Overvoltage category III. The front face with shrouds provides IP20 protection per IEC 60529 and VDE 0106.","metaTitle":"Schneider TeSys F LC1F1000FD Contactor, 1250 A AC-3, EOL","metaDescription":"Schneider Electric TeSys F LC1F1000FD contactor, 1250 A rated operational current (AC-3), 110 V DC coil. End-of-life status. Sourced to order against RFQ. Complies with EN/IEC 6094","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"238.6 mm","Range":"TeSys","Width":"438 mm","Height":"332 mm","Standards":"EN 60947-4-1 IEC 60947-1 EN 60947-1 IEC 60947-4-1","Operating time":"40...80 ms closing 100...200 ms opening","lifecycle_stage":"eol_hot","Mounting support":"Plate","Range of product":"TeSys F","Average impedance":"0.1 mOhm - Ith 1250 A 50 Hz","Device short name":"LC1F","Motor Power Range":"315 kW at 220...230 V 3 phases 560 kW at 380...400 V 3 phases 630 kW at 415 V 3 phases 670 kW at 440 V 3 phases","Poles description":"3P","Compatibility code":"LC1F","Motor starter type":"Direct on-line contactor","Operating altitude":"3000 m without derating","Control circuit type":"DC standard","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-1 AC-3","Contactor application":"Resistive load Motor control","Associated fuse rating":"1400 A gG at <= 440 V","Contactor coil voltage":"110 V DC standard","Maximum operating rate":"600 cyc/h 55 °C","Connections - terminals":"Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²solid without cable end Power circuit: bar 3 cable(s) Power circuit: bar 4 cable(s)","IP degree of protection":"IP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106","Rated breaking capacity":"8 kA conforming to IEC 60947-4-1","Product or component type":"Contactor","Power dissipation per pole":"200 W AC-1","[Uc] control circuit voltage":"110 V DC","[Ui] rated insulation voltage":"1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C","Power Pole Contact Composition":"3 NO","[Ie] rated operational current":"1250 A (at 1000 A (at <55 °C) at <= 440 V AC AC-3","[Ue] rated operational voltage":"<= 440 V AC 50/60 Hz","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-5...40 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"10000 A 40 °C - 10 s 7500 A 40 °C - 30 s 5500 A 40 °C - 1 min 4200 A 40 °C - 3 min 3000 A 40 °C - 10 min","[Ith] conventional free air thermal current":"1250 A (at 40 °C)","Permissible ambient air temperature around the device":"-40...60 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/86a1b7274d33721cd3bab87c72c20985.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC1F1000FD/tesys-f-contactor-3p-3-no-ac3-440-v-1000-a-coil-110-v-dc/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1F1000FD/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy the LC1F1000FD?","answer":"We source the LC1F1000FD to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time. Submit an RFQ with your quantity and delivery needs."},{"question":"What is the rated operational current of the LC1F1000FD?","answer":"The rated operational current is 1250 A in AC-3 duty (motor switching) at <= 440 V AC. The conventional free air thermal current is also 1250 A at 40 °C."},{"question":"What standards does the LC1F1000FD comply with?","answer":"The contactor complies with EN 60947-4-1 and IEC 60947-4-1 (contactor standard), plus EN/IEC 60947-1 (general rules). Rated insulation voltage is 1000 V per IEC 60947-4-1, with an impulse withstand voltage of 8 kV."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1F1000FD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1F1000FD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}