{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1F1000R7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1F1000R7","canonicalUrl":"https://aoctrl.com/schneider/LC1F1000R7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1F1000R7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F contactor, 3P (3 NO), AC-3/AC-1, <=440 V 1000 A, coil 440 V AC, plate mount, end-of-life.","salesMarkdown":"It carries a conventional free-air thermal current (Ith) of 1250 A at 40 °C and a rated operational current (Ie) of 1000 A in AC-3 duty at <=440 V, 50/60 Hz — meaning it can switch a 560 kW motor at 380–400 V three-phase, or up to 670 kW at 440 V. The coil is 440 V AC, 40–400 Hz, with closing time 40–80 ms and opening 100–200 ms. This is a plate-mount device (438 mm wide, 332 mm tall, 238.6 mm deep) with IP20 protection on the front face when shrouds are fitted, per IEC 60529 and VDE 0106. Power connections are via bar terminals; control wiring uses screw clamp terminals accepting 1–4 mm² flexible or solid. ## Key ratings in context The 1000 A AC-3 rating governs motor switching; the 1250 A AC-1 rating covers resistive loads. Rated breaking capacity is 8 kA per IEC 60947-4-1, and the short-time withstand (Icw) is 10 kA for 10 seconds at 40 °C — enough for coordination with upstream fuses up to 1400 A gG at <=440 V. The contactor is rated for 600 cycles per hour at 55 °C. Insulation voltage (Ui) is 1000 V per IEC 60947-4-1, with an impulse withstand (Uimp) of 8 kV and overvoltage category III. The LC1F1000R7 is certified to IEC 60947-4-1, IEC 60947-1, EN 60947-1, and EN 60947-4-1. Protective treatment is TH (tropicalized). The front face with shrouds carries IP20 protection.","metaTitle":"Schneider TeSys F LC1F1000R7 Contactor, 1250 A AC-3, 440 V A","metaDescription":"Schneider Electric TeSys F LC1F1000R7 contactor. 3-pole, 1250 A AC-3 at <=440 V, 440 V AC coil. End-of-life status; sourced to order against RFQ. IEC 60947-4-1.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"238.6 mm","Range":"TeSys","Width":"438 mm","Height":"332 mm","Standards":"IEC 60947-4-1 IEC 60947-1 EN 60947-1 EN 60947-4-1","Operating time":"40...80 ms closing 100...200 ms opening","lifecycle_stage":"eol_hot","Mounting support":"Plate","Range of product":"TeSys F","Average impedance":"0.1 mOhm - Ith 1250 A 50 Hz","Device short name":"LC1F","Motor Power Range":"315 kW at 220...230 V 3 phases 560 kW at 380...400 V 3 phases 630 kW at 415 V 3 phases 670 kW at 440 V 3 phases","Poles description":"3P","Compatibility code":"LC1F","Operating altitude":"3000 m without derating","Control circuit type":"AC at 40...400 Hz","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-3 AC-1","Contactor application":"Motor control Resistive load","Associated fuse rating":"1400 A gG at <= 440 V","Maximum operating rate":"600 cyc/h 55 °C","Connections - terminals":"Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²solid without cable end Power circuit: bar 3 cable(s) Power circuit: bar 4 cable(s)","IP degree of protection":"IP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106","Rated breaking capacity":"8 kA conforming to IEC 60947-4-1","Product or component type":"Contactor","Power dissipation per pole":"200 W AC-1","[Uc] control circuit voltage":"440 V AC 40...400 Hz","[Ui] rated insulation voltage":"1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C","Power Pole Contact Composition":"3 NO","[Ie] rated operational current":"1250 A (at 1000 A (at <55 °C) at <= 440 V AC AC-3","[Ue] rated operational voltage":"<= 440 V AC 50/60 Hz","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-5...40 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"10000 A 40 °C - 10 s 7500 A 40 °C - 30 s 5500 A 40 °C - 1 min 4200 A 40 °C - 3 min 3000 A 40 °C - 10 min","[Ith] conventional free air thermal current":"1250 A (at 40 °C)","Permissible ambient air temperature around the device":"-40...60 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8c998adf1f923a6b948c2af9c66fccac.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC1F1000R7/tesys-f-contactor-3p-3-no-ac3-440-v-1000-a-coil-440-v-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1F1000R7/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1F1000R7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1F1000R7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}