{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1F1154B7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1F1154B7","canonicalUrl":"https://aoctrl.com/schneider/LC1F1154B7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1F1154B7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F LC1F1154B7, 4-pole contactor, 200 A AC-3 rated operational current, 24 V AC 40-400 Hz control circuit, plate-mount.","salesMarkdown":"The Schneider Electric LC1F1154B7 is a TeSys F 4-pole contactor rated for 200 A in AC-3 duty (motor switching) at up to 440 V, with a 24 V AC control coil at 40–400 Hz. It carries motor power ratings from 18.5 kW (AC-4 at 400 V) up to 80 kW (AC-3 at 660–690 V), making it a fit for medium-to-large induction motor loads on pumps, conveyors, or compressors. The contactor is plate-mounted, not DIN-rail — plan for a backplate or sub-panel in the enclosure layout. The 200 A figure is the rated operational current (Ie) in AC-3 utilisation category at ≤ 440 V and ≤ 55 °C — that is the motor-switching current, not the resistive-load (AC-1) rating. For AC-1 duty the thermal current (Ith) is higher, but the AC-3 value governs motor contactor sizing. The 55 kW at 400 V AC-3 is the typical three-phase motor it can switch under IEC 60947-4-1. The 4 NO power poles mean all four main contacts close on coil energisation; there are no normally-closed power poles on this variant. The control circuit is 24 V AC, 40–400 Hz, with a hold-in consumption of 8.9–10.9 VA. The coil holds between 0.85 and 1.1 Uc at 55 °C and drops out between 0.2 and 0.55 Uc — important for brownout ride-through planning. Operating time is 35 ms closing, 130 ms opening at rated control voltage. Standards compliance includes IEC 60947-4-1, IEC 60947-1, EN 60947-4-1, EN 60947-1, and JIS C8201-4-1. The rated insulation voltage (Ui) is 1000 V per IEC 60947-4-1, 1500 V per VDE 0110 group C. Overvoltage category III. The contactor carries TH protective treatment for tropical environments. Mounts on a plate (not DIN rail). Dimensions: 162 mm height, 163.3 mm width, 171 mm depth. Power circuit accepts bar connections (up to 20 x 3 mm busbar), ring-terminal lugs (1 x 95 mm²), or bolted connection; torque to 10 N·m. Control circuit uses screw-clamp terminals accepting 1–4 mm² flexible or solid, torque to 1.2 N·m. The IP2X front face requires shrouds per IEC 60529.","metaTitle":"Schneider Electric LC1F1154B7 TeSys F Contactor, 200 A AC-3,","metaDescription":"Schneider Electric LC1F1154B7 TeSys F 4-pole contactor. 200 A rated operational current (AC-3), 55 kW at 400 V. IEC 60947-4-1. End-of-life; sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"171 mm","Range":"TeSys","Width":"163.3 mm","Height":"162 mm","Standards":"IEC 60947-4-1 IEC 60947-1 EN 60947-4-1 EN 60947-1 JIS C8201-4-1","Motor power kW":"55 kW at 380...400 V AC 50/60 Hz (AC-3) 59 kW at 415 V AC 50/60 Hz (AC-3) 59 kW at 440 V AC 50/60 Hz (AC-3) 75 kW at 500 V AC 50/60 Hz (AC-3) 80 kW at 660...690 V AC 50/60 Hz (AC-3) 30 kW at 220...230 V AC 50/60 Hz (AC-3) 18.5 kW at 400 V AC 50/60 Hz (AC-4)","Operating time":"35 ms closing (at Uc) 130 ms opening (at Uc)","lifecycle_stage":"eol_hot","Heat dissipation":"5.9...7.2 W","Mounting support":"Plate","Range of product":"TeSys F","Average impedance":"0.37 mOhm - Ith 200 A 50 Hz","Device short name":"LC1F","Poles description":"4P","Tightening torque":"Power circuit: 10 N.m Control circuit: 1.2 N.m","Compatibility code":"LC1F","Inrush power in VA":"690...855 VA, 40...400 Hz cos phi 0.9 (at 20 °C)","Operating altitude":"3000 m without derating","Control circuit type":"AC at 40...400 Hz","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-3 AC-1 AC-4","Contactor application":"Resistive load Motor control","Mechanical durability":"10 Mcycles","Associated fuse rating":"125 A aM at 200 A gG at <= 440 V","Maximum operating rate":"2400 cyc/h 55 °C","Connections - terminals":"Power circuit: bar 2 cable(s) - busbar cross section: 20 x 3 mm Power circuit: lugs-ring terminals 1 cable(s) 95 mm² Power circuit: connector 1 cable(s) 95 mm² Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²solid without cable end Power circuit: bolted connection","IP degree of protection":"IP2X front face with shrouds conforming to IEC 60529 IP2X front face with shrouds conforming to VDE 0106","Rated breaking capacity":"920 A conforming to IEC 60947-4-1","Product or component type":"Contactor","Power dissipation per pole":"15 W AC-1 5 W AC-3","[Uc] control circuit voltage":"24 V AC 40...400 Hz","[Ui] rated insulation voltage":"1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C","Control circuit voltage limits":"Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C) Drop-out: 0.2...0.55 Uc 40...400 Hz (at 55 °C)","Power Pole Contact Composition":"4 NO","[Ie] rated operational current":"200 A (at 115 A (at <55 °C) at <= 440 V AC-3","[Ue] rated operational voltage":"<= 690 V AC 50/60 Hz","Hold-in power consumption in VA":"8.9...10.9 VA, 40...400 Hz cos phi 0.9 (at 20 °C)","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-40...60 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"1100 A 40 °C - 10 s 640 A 40 °C - 30 s 520 A 40 °C - 1 min 400 A 40 °C - 3 min 320 A 40 °C - 10 min","[Ith] conventional free air thermal current":"200 A (at 40 °C)","Permissible ambient air temperature around the device":"60...70 °C at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/88e71e1475f96f4a77c24c2c469df55c.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC1F1154B7/tesys-f-contactor-4p-4-no-ac3-440-v-115-a-coil-24-v-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1F1154B7/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to LC1F1154B7 in the TeSys F family?","answer":"No official successor order code is recorded for this exact variant. A functionally similar TeSys F contactor with the same 200 A AC-3 rating and 4-pole configuration would need to match the 24 V AC control voltage and plate-mount footprint — verify the coil code and pole arrangement against the current TeSys F catalog under change control."},{"question":"What is LC1F1154B7's motor power rating at 400 V?","answer":"At 380–400 V AC 50/60 Hz in AC-3 duty, the contactor is rated for 55 kW. In AC-4 duty (plugging/reversing) at 400 V, the rating is 18.5 kW."},{"question":"Where can I buy LC1F1154B7 and how is it quoted?","answer":"Sourced to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time; no manufacturer-backed stock remains."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1F1154B7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1F1154B7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}